Embedded 4-Gigabit Fibre Channel to SCSI bridge
ATTO FibreBridge 2390C/R/D
Multiple form factor 4-Gigabit Fibre Channel to SCSI bridge
ATTO FibreBridge 2400C/R/D
Multiple form factor 4-Gigabit Fibre Channel to SCSI bridge

Advertisement

Table of Contents
loading

Summary of Contents for ATTO Technology FibreBridge 2370E

  • Page 1 ATTO FibreBridge Installation and Operation Manual ATTO FibreBridge 2370E Embedded 4-Gigabit Fibre Channel to SCSI bridge ATTO FibreBridge 2390C/R/D Multiple form factor 4-Gigabit Fibre Channel to SCSI bridge ATTO FibreBridge 2400C/R/D Multiple form factor 4-Gigabit Fibre Channel to SCSI bridge...
  • Page 2 © 2008 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology, Inc.
  • Page 4: Table Of Contents

    1.0 ATTO FibreBridge Provides Storage Options ...1 ATTO FibreBridge 2370E features, benefits ATTO FibreBridge 2390C/R/D features, benefits ATTO FibreBridge 2400C/R/D features, benefits 1.1 ATTO FibreBridge 2370E Physical Attributes ...3 Board dimensions Cooling and airflow Power Fibre Channel port SCSI ports...
  • Page 5 2.0 Install the FibreBridge ...13 Unpack the packing box; verify contents Install the FibreBridge Discover the IP address Internet Explorer setup Begin initial configuration 3.0 Configure the FibreBridge ...15 Preliminary steps Page descriptions 3.1 Map Devices ...17 FibreBridge mapping SCSI device mapping Mapping devices automatically Mapping devices manually.
  • Page 6: Atto Fibrebridge Provides Storage Options

    Fibre Channel hardware. ATTO FibreBridge 2370E features, benefits The ATTO FibreBridge 2370E is a Fibre Channel-to- SCSI bridge that offers a high-performance architecture supporting next-generation storage media. The FibreBridge 2370E allows users with SCSI storage to add Fibre Channel connectivity, enabling SAN connectivity for the storage system.
  • Page 7: Atto Fibrebridge 2400C/R/D Features, Benefits

    • SFP FC connector • Support for direct connect to F-port fabric switches, full duplex FC data transfers and FC- AL, PLDA and public look login • Two independent Ultra320 SCSI buses • Dual-stacked VHDCI SCSI connectors • Backward compatible with all single-ended SCSI devices and all previous SCSI protocols •...
  • Page 8: Atto Fibrebridge 2370E Physical Attributes

    1.1 ATTO FibreBridge 2370E Physical Attributes The ATTO FibreBridge 2370E is a 4-Gigabit Fibre Channel to SCSI bridge offering the ability to add 4-Gigabit Fibre Channel connectivity to Ultra320 SCSI devices. The FibreBridge 2370E is available in an embeddable card for easy integration into storage devices.
  • Page 9 Exhibit 1.1-1 FibreBridge 2370E board layout...
  • Page 10: Atto Fibrebridge 2390R/D Physical Attributes

    Dispose of used batteries in accordance with your local environmental regulations. ATTO Technology Inc. FibreBridge Installation and Operation Manual Explosionsgefahr, wenn die Batterie falsch entfernt und/oder ersetzt wird. Entsorgen Sie benutzte Batterien in Übereinstimmung mit Ihren lokalen Umweltschutzbestimmungen.
  • Page 11: Dimensions

    A bicolor Ready/Fault LED lights green to indicate ready, lights yellow to show a faulted condition, and is off to indicate not ready. Embedded in the Ethernet port connector: a lighted green LED shows a valid link; off indicates that no link is present.
  • Page 12: Atto Fibrebridge 2390C Physical Attributes

    The battery is fully charged after 24 hours of continuous power application. ATTO Technology Inc. FibreBridge Installation and Operation Manual Fibre Channel port The 4-Gb Fibre Channel port uses a Small Formfactor Pluggable (SFP) interface.
  • Page 13 no link is present. A separate blinking yellow LED indicates activity. Exhibit 1.3-1 The FibreBridge 2390C connectors and LEDS. Exhibit 1.3-2 The FibreBridge 2390C board layout. A bicolor Ready/Fault LED lights green to indicate ready, lights yellow to show a faulted condition, and is off to indicate not ready.
  • Page 14: Atto Fibrebridge 2400R/D Physical Attributes

    Dispose of used batteries in accordance with your local environmental regulations. ATTO Technology Inc. FibreBridge Installation and Operation Manual Explosionsgefahr, wenn die Batterie falsch entfernt und/oder ersetzt wird. Entsorgen Sie benutzte Batterien in Übereinstimmung mit Ihren lokalen Umweltschutzbestimmungen.
  • Page 15: Led Indicators

    LED indicators The LED indicators can be viewed from the connector side and the front side of the FibreBridge 2400R/D. (See Exhibit 1.4-1) LEDs on the connector side are: A bicolor Ready/Fault LED lights green to indicate ready, lights yellow to show a faulted condition, and is off to indicate not ready.
  • Page 16: Atto Fibrebridge 2400C Physical Attributes

    The battery is fully charged after 24 hours of continuous power application. ATTO Technology Inc. FibreBridge Installation and Operation Manual Fibre Channel port The dual independent 4-Gb Fibre Channel ports can...
  • Page 17 Exhibit 1.5-1 FibreBridge 2400C bracket detail and board layout mounting hole 10-pin serial header Ready/Fault LED Ethernet port FC activity & link LEDs cPCI connector Fibre Channel ports SCSI ports SCSI activity LEDs 6.1939 inches m ounting hole cPC I connector 10-pin Pow er serial...
  • Page 18: Install The Fibrebridge

    2400C, power is already connected if you have installed the unit using the cPCI connection. ATTO Technology Inc. FibreBridge Installation and Operation Manual • For the FibreBridge 2390R/D and the FibreBridge 2400R/D, connect the AC power cord from the FibreBridge to the proper AC source outlet and turn on the power using the power switch.
  • Page 19: Internet Explorer Setup

    If you do not have a DHCP server, get an IP address and subnet mask from your network administrator, type it into the area provided, and click on Next . Click on Launch Browser. Your browser points to the ATTO ExpressNAV splash screen.
  • Page 20: Configure The Fibrebridge

    • Port names • Fibre Channel port status • SCSI port status • World Wide Identifiers of ports and nodes ATTO Technology Inc. FibreBridge Installation and Operation Manual on page 17. The Status page appears. Click on the element in the left-hand menu to observe settings or to change parameters.
  • Page 21 SCSI configuration Each SCSI port is configured separately. Displays include a list of attached devices for each bus. Configurable options are: • Port bus speed • Synchronous transfer • Wide transfer • Initiator ID • Bus reset on startup • Bus termination •...
  • Page 22: Map Devices

    SCSI portion of the FibreBridge. The FibreBridge SCSI ID must be set to a different SCSI ID from the other devices on the same bus. ATTO Technology Inc. FibreBridge Installation and Operation Manual 3.1 Map Devices The ATTO ExpressNAV interface graphically shows you current mapping and the SCSI devices available for mapping.
  • Page 23: Multiple Node Addressing (Fb2400 Only)

    Here, type in your user name and password, and click OK . The Status page appears. From the ExpressNAV main menu, click on the Mapping menu item on the left side of the screen. Multiple Node addressing (FB2400 only) The FibreBridge has a unique Port name for each Fibre Channel port.
  • Page 24: Monitor, Manage Remotely

    Exhibit 3.0-3 The Remote Management page in the ExpressNAV interface. ATTO Technology Inc. FibreBridge Installation and Operation Manual You may designate which warning level a recipient receives. For example, a recipient with a critical severity level only receives critical messages and not warning or informational messages.
  • Page 25: Snmp-Based Monitoring

    SNMP-based monitoring The Simple Network Management Protocol (SNMP) facilitates the exchange of management information between network devices. An agent resides in the FibreBridge which takes information from the FibreBridge and translates it into a form compatible with SNMP. If certain conditions arise, the agent sends asynchronous notifications (traps) to a client.
  • Page 26: Email Messages Provide Error Notification

    SMTP header information as shown in Exhibit 3.0- If you are not already in the ExpressNAV interface, type the IP address of your ATTO Technology Inc. FibreBridge Installation and Operation Manual Extended Traps enabled Unit’s internal temperature has increased to at or within the unit’s maximum operating temperature...
  • Page 27 Exhibit 3.0-5 The Email messages sent by the FibreBridge follow this format. Subject: [The Type of Event that Occurred] Message Body: This is a status message from [FibreBridge name]. Identifying information as well as the most recent entries from the event log appear below. *************** Unit Information Serial Number : [Serial Number] IP Addresses:...
  • Page 28: Modify System Values

    OK . The Status page appears. Choose the page you need. ATTO Technology Inc. FibreBridge Installation and Operation Manual Modify passwords Follow the Preliminary steps. From the side menu select Bridge . on page 27. The Bridge Configuration page is displayed.
  • Page 29 SCSI device uses SpeedWrite performance enhancement by default. Follow the Preliminary steps. From the left hand menu, click on Storage Management. Select the parameters you wish to change. Click Submit. If you have completed all changes for this session, go to the Restart page and restart the FibreBridge.
  • Page 30: Update Firmware

    FibreBridge until the display returns the Ready prompt. Interrupting the flash process will make your FibreBridge inoperable and you will have to return it to ATTO Technology for repair. If you are not already in the ExpressNAV interface, type the IP address of your FibreBridge in a standard browser as found in ATTO Technology Inc.
  • Page 32: Interface Options

    Windows operating system, a. Type FibreBridge in the New Connection dialogue box. ATTO Technology Inc. FibreBridge Installation and Operation Manual 6.0 Interface options Each page can be reached through the menu at the side of each page. An image on each page’s header shows each port in the product faceplate.
  • Page 33: Using Telnet

    • Flow Control: None • Terminal type: ASCII • Echo: on f. Click OK. After you connect to the FibreBridge, start-up messages are displayed. These messages are only displayed at start-up. The last line in the start-up message sequence is Ready . In serial port sessions, there is no prompt on the line below the word Ready .
  • Page 34: Appendix A Cabling

    (LVD) Ultra160 SCSI Low Voltage Differential (LVD) Ultra320 SCSI Low Voltage Differential (LVD) ATTO Technology Inc. FibreBridge Installation and Operation Manual Appendix A Cabling Fibre Channel connections Fibre Channel technology offers a variety of cabling options. The type of cable required varies depending upon the application, environment and distance.
  • Page 35: Appendix B Cli Provides Ascii-Based Interface

    Appendix B The command line interface (CLI) provides access to the ATTO FibreBridge Services through a set of ASCII commands. CLI commands may be entered while in CLI mode. FibreBridge Services provide configuration and monitoring for the FibreBridge. The command line interface (CLI) is a set of ASCII-based commands which perform these tasks.
  • Page 36: Cli Error Messages

    DumpConfiguration DumpEventLog DumpTraceLog EmailFromAddress EmailNotify EmailNotifyAddress EmailPassword EmailServerAddress EmailUsername EthernetSpeed EventLog EventLogFilter ATTO Technology Inc. FibreBridge Installation and Operation Manual Default Example disabled set autologsense enabled automap set bootfibredelay 15 disabled set bootscan enabled auto set bootscanports all get bridgemodel “...
  • Page 37 Command Exit FCConnMode FCDataRate FCHard FCHardAddress FCMultiNode (FB 2400) FCPortErrors FCPortList FCSCSIBusyStatus FCSpeedLED2G (FB 2370) FCWWName FirmwareRestart Help IdentifyBridge Info IPAddress IPDHCP IPDNSServer IPGateway IPSubnetMask IsReserved LogicalUnitAddressing MaxOpTemp (FB 2390, FB 2400} MinOpTemp (FB 2390, FB 2400} OpTempWarn (FB 2390, FB 2400} Password Performance Ping...
  • Page 38 TraceLog TraceLogFilter Username VerboseMode VirtualDriveResponse VirtualRobotResponse Voltage (FB 2390, FB 2400} WrapEventLog WrapTraceLog zModem ATTO Technology Inc. FibreBridge Installation and Operation Manual Default Example ultra320 set scsiportbusspeed 2 ultra160 scsiportlist scsiportreset 1 enabled set scsiportresetonstartup 1 disabled enabled set scsiportsynctransfer 2 disabled...
  • Page 39: Command Explanations

    Command explanations AutoLogSense Controls whether current data from log pages in a SCSI target device is available automatically. Default: disabled set AutoLogSense [enabled|disabled] Requires a SaveConfiguration command get AutoLogSense AutoMap Automatically assigns a subset of source protocol LUNs to a subset of target destination devices visible to the FibreBridge.
  • Page 40 Email server. Full Email address is a fully qualified Internet Email address, not more than 128 characters long. set EmailFromAddress [full email address] get EmailFromAddress ATTO Technology Inc. FibreBridge Installation and Operation Manual EmailNotify Regulates Email notification. Default: disabled. set EmailNotify [enabled | disabled]...
  • Page 41 EventLog Regulates event logging. When enabled, records various system events to the event log. Default: enabled set EventLog [enabled | disabled] get EventLog EventLogFilter Filters data from specific unit subsystems and levels when event logging is enabled. The specific entries supported are platform-dependent.
  • Page 42 IPAddress [mp1] [xxx.xxx.xxx.xxx] Requires a SaveConfiguration Restart command get IPAddress [mp1] ATTO Technology Inc. FibreBridge Installation and Operation Manual IPDHCP Selecting DHCP allows the FibreBridge to request an IP address from the network. The network must have at least one DHCP server.
  • Page 43 MaxOpTemp (FB 2390, FB 2400) Regulates/displays the maximum enclosure temperature alarm of the FibreBridge in degrees Celsius. If the temperature of the FibreBridge rises above the maximum MaxOpTemp, thermal control event handling occurs.Valid entries are between 55 degrees and 70 degrees. Default: 70 set MaxOpTemp [55-70] Requires a SaveConfiguration Restart command...
  • Page 44 Reboot the FibreBridge after running this test. SCSIDomainValidation ATTO Technology Inc. FibreBridge Installation and Operation Manual SCSIInitID Specifies or reports the SCSI initiator ID on the specified SCSI port as found in NVRAM.
  • Page 45 SCSIPortWideTransfer Specifies whether wide SCSI transfers should be negotiated. Enabled allows wide transfer negotiation. Default: enabled set SCSIPortWideTransfer [sb] [enabled | disabled ] Requires a SaveConfiguration command get SCSIPortWideTransfer [sb] SCSITargetLUNs Controls the maximum number of SCSI LUNs per target the FibreBridge queries during a SCSI bus scan.
  • Page 46 Time [HH :MM :SS] Requires a SaveConfiguration command get Time xiii ATTO Technology Inc. FibreBridge Installation and Operation Manual TimeZone Controls/displays the time zone if may be EST, CST, MST PST or a numerical offset from GMT in the format +/- HH:MM. When time zone setting to the time retrieved from a specified SNTP time server to determine local time.
  • Page 47 VirtualRobotResponse Provides proxy responses to SCSI INQUIRY commands if an existing SCSI command is outstanding to a Media Changer. All other SCSI commands are returned with a NOT READY check condition. Default: disabled set VirtualRobotResponse [enabled | disabled] Requires a SaveConfiguration restart command get VirtualRobotResponse Voltage (FB 2350, FB 2400) Displays the voltage levels monitored by the FibreBridge.
  • Page 48: Appendix C Standards And Compliances

    CE standards and found to be compliant. The ATTO FibreBridge 2370E, 2390 and 2400 comply with Directive 2002/95/EC on the Restriction of the Use of Hazardous Substances in Electrical and Electronic Equipment (RoHS).
  • Page 49 Certification for the FibreBridge 2400 only UL60950-1/CSA C22.2 No. 60950-1...
  • Page 50: Appendix D Warranty Information

    Manufacturer. Manufacturer’s liability xvii ATTO Technology Inc. FibreBridge Installation and Operation Manual Warranty Information is limited to Manufacturer’s product(s); damage to other equipment connected to Manufacturer’s product(s) will be the customer’s responsibility.