2.5.5 SCSI configuration commands
The SCSI ports are configured with default settings but may be customized to your specifications using
the CLI commands in this section. Any commands which require Ethernet are not available for ATTO
FibreBridge 1180 models. Refer to the
commands apply to your model.
AutoLogSense
Controls Automatic LOG SENSE functionality.
Default:
Set syntax: set AutoLogSense [enabled|disabled]
Requires a SaveConfiguration command
Get syntax: get AutoLogSense
FCSCSIBusyStatus
Specifies the SCSI status value returned when the
FibreBridge is unable to accept a SCSI command
because of a temporary lack of resources. Choices are
busy and qfull.
Default: busy
Set syntax: set FcSCSIBusyStatus [busy | qfull]
Requires a SaveConfiguration command
Get syntax: get FcSCSIBusyStatus
FixedLengthReqSense
Specifies that the bridge will pad the number of bytes of
autosense data returned as a result of a CHECK
Condition to a "mod 4" length.
Set stands: set FixedLengthReqSense [enabled |
disabled]
Requires a SaveConfiguration command
Get syntax: get FixedLengthReqSense
SCSIInitID
Specifies or reports the SCSI initiator ID on the specified
SCSI port as found in NVRAM. All maps coinciding with
the user-specified SCSIInitID must be set to offline and
will become invalid upon issuing this command. The set
command always modifies NVRAM, whether you use a
SaveConfiguration command or not.
Default: 7
Set syntax: set SCSIInitID [sb [0-15] ]
Get syntax: get SCSIInitID
53
ATTO Technology Inc. FibreBridge Installation and Operation Manual
CLI summary reference
SCSIInitID (FB 2400 only)
Specifies or reports the SCSI initiator ID on the specified
SCSI port as found in NVRAM. All maps coinciding with
the user-specified SCSIInitID will be destroyed after the
command is issued.
Default: 7
Set syntax: set SCSIInitID [sb [0-15] ]
Get syntax: get SCSIInitID
SCSIPortBusSpeed
Controls the transfer rate at which the FibreBridge will
attempt to negotiate with its SCSI devices. Valid options
are Fast SCSI, Ultra SCSI, Ultra 2 SCSI, Ultra 3 SCSI
and Ultra 4 SCSI. Ultra2 and Ultra 3 are valid only if
FibreBridge has LVD-capable SCSI ports.The
FibreBridge 1180 only supports Ultra2 or slower speeds;
all other FibreBridge models also support higher speeds.
Default: see
Set syntax: set SCSIPortBusSpeed [Port Number [ fast |
ultra | ultra2 | ultra3 | ultra4]
Requires a SaveConfiguration command
Get syntax: get SCSIPortBusSpeed
SCSIPortList
Returns a list of available SCSI ports and their current
status. Valid status values are OK and Failed
Get syntax: SCSIPortList
SCSIPortReset
Resets the specified SCSI bus.
Set syntax: SCSIPortReset [sb]
SCSIPortResetOnStartup
Specifies if the SCSI port should be reset on power-up.
Default: enabled
Set syntax: set SCSIPortResetOnStartup [sb [enabled |
disabled] ]
Requires a SaveConfiguration command
Get syntax: get SCSIPortResetOnStartup [sb]
on page 41 to determine which CLI