2.5.4 Maintenance commands
The CLI commands outlined in this chapter may be used to get information or perform functions which
are used in a variety of situations with the ATTO FibreBridge. Any commands which require Ethernet
are not available for ATTO FibreBridge 1180 models. Refer to the
to determine which CLI commands apply to your model.
Date
Sets/displays the date. The range is 01/01/2000 to
12/31/2099. For all models except the FibreBridge 2350,
the date will be reset to the default after the FibreBridge
is reset or power-cycled. The date is persistent in the
FibreBridge 2350 because it has a battery backup.
Default: 01/01/2000
Set syntax: set Date [MM] / [DD] / [YYYY]
Requires a SaveConfiguration command
Get syntax: get Date
FirmwareRestart
Causes the FibreBridge to reboot, then re-initialize its
firmware.
Immediate: FirmwareRestart
FixedLengthReqSense
If enabled, forces the FibreBridge to pad the number of
bytes of autosense data returned as a result of a CHECK
CONDITION to a mod 4 length.
Default: disabled
Set syntax: set FixedLengthReqSense [enabled |
disabled]
Requires a SaveConfiguration command
Get syntax: get FixedLengthReqSense
IsReserved
Displays the reservation status of the current FibreBridge
session/interface.
Immediate command: IsReserved
MaxOpTemp
Sets/displays the maximum enclosure temperature alarm
of the unit in degrees Celsius. If the temperature of the
FibreBridge rises above the maximum MaxOpTemp,
thermal control event handling occurs.Valid entries are
between 55 and 70 degrees
°
Default: 70
C
Set syntax: set MaxOpTemp [55-70]
Requires a SaveConfiguration command
Get syntax: get MaxOpTemp
51
ATTO Technology Inc. FibreBridge Installation and Operation Manual
CLI summary reference
MinOpTemp
Sets/displays the minimum enclosure temperature alarm
of the unit in degrees Celsius. If the temperature of the
FibreBridge falls below the minimum MinOpTemp,
thermal control event handling occurs.Valid entries are
between 0 and 15 degrees
º
Default: 0
C
Set syntax: set MinOpTemp [0-15]
Requires a SaveConfiguration command
Get syntax: get MinOpTemp
OpTempWarn
Sets/displays the number of degrees in Celsius before a
thermal control event handling occurs. Warnings will be
made via SNMP traps and system log entries. Valid
entries are between 0 and 15 degrees
º
Default: 5
C
Set syntax: set OpTempWarn [0-15]
Requires a SaveConfiguration command
Get syntax: get OpTempWarn
Reserve
Prevents other CLI sessions from modifying the
FibreBridge. When the FibreBridge services interface is
reserved, set commands are unavailable but get
commands are available. At least one service interface
always has access to the FibreBridge at all times. This
interface always reports RELEASED status, since it
may issue set commands. Reservation of the FibreBridge
is implicit: if the configuration is changed by any user of
CLI sessions, the FibreBridge becomes RESERVED.
Executing a SaveConfiguration command,
RestoreConfiguration or FirmwareRestart releases
the FibreBridge so that other devices may modify it.
Immediate: Reserve
RestoreConfiguration
Restores configuration to either the default configuration
or the configuration last saved into non-volatile memory.
The saved option will undo any changes made since the
last save.
Immediate: RestoreConfiguration [Default | Saved]
on page 41