ATTO Technology FibreBridge 1180D Installation And Operation Manual page 60

Atto technology fibrebridge 1180d bridges: user guide
Hide thumbs Also See for FibreBridge 1180D:
Table of Contents

Advertisement

SNMPTrapAddress
Sets/displays the IP trap addresses and levels.
Index: value between 1 and 6
IP Address: standard IP address
Trap Level: severity required for an event to trigger a trap:
...None: no traps will be sent to the address
...ALL: all triggering events will be sent
...Informational: a trap will be issued to the given address
...Warning: warning and critical events will be sent
...Critical: only critical events will trigger a trap
Set syntax: set SNMPTrapAddress [Index] [IPAddress]
[level]
Get syntax: get SNMPTrapAddress
SNMPTraps
Enables/disables SNMP trap functions.
Default: disabled
Set syntax: set SNMPTraps [enabled | disabled]
Get syntax: get SNMPTraps
SNMPExtendedTraps
Enables/disables extended traps such as device transition
and device error. Not available for the FibreBridge 2400.
Default: disabled
Set syntax: set SNMPExtendedTraps [enabled|disabled]
Get syntax: get SNMPExtendedTraps
Temperature
Returns the current internal temperature of the unit in
degrees Celsius.
Information only: get Temperature
TraceLog
When enabled, records various aspects of the FC-SCSI
traffic it receives to the trace log.
Default: disabled
Set syntax: set TraceLog [enabled | disabled]
Get syntax: get TraceLog
49
ATTO Technology Inc. FibreBridge Installation and Operation Manual
TraceLogFilter
Filters the display of data for specific FibreBridge
subsystems when in TraceLog mode. If enabled for a
particular subsystem and level, that subsystem and level
will be masked when the command TraceLogFilter is
issued.
Default: disabled
Set syntax: set TraceLogFilter [FC | SCSI | ALL] [fp |sb |
ALL] [enabled | disabled]
Get syntax: get TraceLogFilter [FC |SCSI |ALL ] [fp |sb |
ALL ]
Voltage
Displays the voltage levels monitored by the FibreBridge
2350 and the FibreBridge 2400.
VCC: +5.03 V
VDDA: +3.31 V
VDDB: +2.49 V
VDDC: +1.5V
VDDD: +1.35V
ALL: all monitored voltages
Information only: get Voltage <VCC | VDDA |VDDB |ALL>
WrapEventLog
When enabled, the FibreBridge will log up to 2,048 event
entries before wrapping (overwriting the first entries). If
disabled, the FibreBridge stops logging event entries
when the buffer is full.
Default: enabled
Set syntax: set WrapEventLog [enabled | disabled]
Get syntax: get WrapEventLog
WrapTraceLog
When enabled, the FibreBridge will log up to 2,048 trace
entries before wrapping (overwriting the first entries). If
disabled, the FibreBridge stops logging trace entries
when the buffer is full.
Default: enabled
Set syntax: set WrapTraceLog [enabled | disabled]
Get syntax: get WrapTraceLog
XCDevices
Allows the user to get information about the devices used
in a particular Extended Copy command specified by the
CmdNumber as presented in the XCStatus CLI command
(see below). DeviceType displays SCSI device type.
VendorId, Product Id, SerialNumber display SCSI inquiry
data for each device. DataDirection specifies whether a
device is a data source, a data destination or both.
Information only: get XCDevices [CmdNumber]

Advertisement

Table of Contents
loading

Table of Contents