9. Align the back of the riser assembly to the slot guides on the chassis back panel (see Letter A).
10. Carefully lower the riser assembly into the chassis, ensuring the edge connector of the riser card
aligns with the riser slot on the server board.
11. Insert the riser card into the slot using even downward pressure until the assembly is fully seated.
12. Push down on the blue tab on the end of the rise assembly and turn it clockwise until the riser
assembly is locked in place to the server board (see Letter B).
13. Fold down the blue tab.
Note: Ensure all internal cables attached to the riser card and/or add-in card are cleanly routed using cable
management features. See
3.2.4
PCIe* Add-in Card Removal – Riser Card
The following illustrations reference the Riser 1 assembly. However, the instructions to add or remove an
add-in card is the same regardless of riser card assembly location.
Required Tools and Supplies
•
Anti-static wrist strap and conductive workbench pad (recommended)
System Prerequisites
•
The system must be powered off and AC Power cord(s) disconnected
•
Disconnect all cables (External and Internal) attached to riser assembly
37
Intel® Server System M70KLP Family Service Guide
Figure 41. Riser Card Installation into System
Section
2.3. Clean cable routing will be necessary to reinstall the air duct.