Air Duct Removal; Figure 2. System Top Cover Removal; Figure 3. Chassis Intrusion Switch Cable Connection On Server Board - Intel M70KLP Series Service Manual

Hide thumbs Also See for M70KLP Series:
Table of Contents

Advertisement

1. Using a phillips screw driver, rotate the latch lock ¼ turn to the "Unlock" position (see Letter A).
2. Lift the latch to its full open position. The top cover will slide back (see Letter B).
3. Lift the back edge of the top cover, then slide the top cover back and away from the chassis
(see Letter C).
2.1.2

Air Duct Removal

Note: Instructions will be identical regardless of air duct type installed (Standard or Low Profile)
The air duct is held in place using a lock bar that must be removed prior to removing the air duct. Integrated
within the lock bar assembly is a chassis intrusion switch that is cabled to the server board. This cable must
be carefully disconnected from the server board before removing the lock bar.

Figure 3. Chassis Intrusion Switch Cable Connection on Server Board

1. Located below the back edge of the air duct, unlatch and disconnect the white two-wire chassis
intrusion switch cable from the server board (see
DO NOT pull on the wires to disconnect the cable. Doing so may detach the wires from the
connector.
Intel® Server System M70KLP Family Service Guide

Figure 2. System Top Cover Removal

2. Pull-up
Figure
3).