3.6.2

M.2 SSD Removal

1. Remove the fastener pin from the back edge of the M.2 SSD (see Letter A).
2. Grasp the SSD by its edges and carefully pull it from the M.2 slot (see Letter B).
3.7 Intel® RAID Maintenance Free Backup Unit (RMFBU) Installation / Removal
This section provides instructions for the installation and removal of the Intel® RMFBU accessory.
Depending on the system configuration, the Intel® Server System M70KLP supports up to three Intel® RMFBU
accessories (Standard System) or one Intel® RMFBU (GPU supported system). In either system configuration,
the Intel® RMFBU is mounted to the top side of the system air duct as shown in
To support three RMFBUs in a standard system, two RMFBUs are stacked on top of each other with the third
mounted next to them.
Standard Air Duct
Intel® Server System M70KLP Family Service Guide

Figure 58. M.2 SSD Removal

Figure 59. Intel® RMFBU Placement
Figure
59.
GPU Enabled Air Duct
48