Intel® Server System M70KLP Family Service Guide

Figure 106. PHM Installation onto Server Board

1. Set all four anti-tilt wires on the heat sink to the inward position (see Letter A).
2. Align the pin 1 indicators of the processor carrier clip and processor with the pin 1 indicator on the
socket assembly bolster plate.
3. Carefully lower the PHM over the four bolster plate alignment pins (see Letter B).
4. Ensure the PHM is sitting flat and even on the bolster plate.
5. Set all four anti-tilt wires on the heat sink to the outward position (see Letter C).

Figure 107. Tighten Heat Sink Fasteners

6. Using a T30 Torx* screwdriver, tighten (in order 1,2,3,4) the heat sink fasteners to 8 in-lb.
7. Reinstall the air duct and system cover (see
Sections 2.2.1
and 2.2.2).