Tm1 Timer - Safeline Signature Operating And Instruction Manual

Table of Contents

Advertisement

!
CAUTION
Ensure you have read the REJECT TIMERS
INTRODUCTION section on page 78
Introduction
The tm1 timer is used in applications requiring instant
rejection of contaminated products.
This timer type can be used with either packaged or
loose product.
Setting Timer type tm1
The display opposite may be used to either:
a) Select which timer group the current product
number should use,
or,
b) Select which timer group the current product
number should use AND adjust the timer group
settings such as timer type, reject time, etc.
NOTE
If you have already selected the timer group and
pressed YES to updating the group, as per the
Engineer Mode section earlier, then proceed to
step 3).
1) Press the soft key adjacent to the required group
letter, A, B or C.
2)
If you only need to select the timer group for the
current product number and not adjust any of the
timer group properties then
a) Select the soft key adjacent to NO, and go
back to the Engineer Mode section.
!
CAUTION
Although NO was selected the group will be changed
to the group letter selected in 1).
else
b) Select the soft key adjacent to YES, and
proceed to step 3)
4618-021
OPERATING INSTRUCTIONS

tm1 TIMER

NOTE
Remember to record all settings on the Settings
Sheets at the rear of the manual.
tm1 settings
a) Reject Time
This is the time required by the reject device to
reject the contaminated product.
The currently selected timer group will be indicated by a flashing
In the following displays 'X' represents the timer group A, B or C as
selected at step 1); tmxx represents the timer type that is currently
selected for this timer group.
cursor appearing over the group letter.
81