5)
Press the soft key adjacent to SIGNAL DELAY
a) Place the metal contaminant at the rear or trailing
edge of the product package.
b) Pass the product with the metal contaminant
attached through the detector aperture, ensuring
that the product does not slip or skew.
c) Use the cursor Up and Down keys to adjust the
Signal Delay so that the reject device operates just
as the front edge of the pack reaches it.
6)
Press the soft key adjacent to REJECT TIME.
a) Place the metal contaminant at the rear / trailing
edge of the product package.
b) Pass the product with the metal contaminant
attached through the detector aperture, ensuring
that the product does not slip or skew.
c) Use the cursor Up and Down keys to adjust the
Reject Time in a way that would reject the pack if it
was positioned correctly.
We are not attempting to reject the product at this
time !
7)
Press the Enter key to accept the new
settings.
8)
Press the Enter key a second time to
proceed to the next display.
9)
Press the soft key adjacent to YES.