b) For loose products
i) Check the setting of tm3 by passing the
product and metal contaminant through the
aperture of the detector.
ii) Check the reject device operates correctly
with the metal contaminant at different
positions on the conveyor belt.
iii) Check the reject device operates correctly
with different sizes of metal contaminant.
iv) Also check the reject device operates
correctly with two metal contaminants
spaced at different distances apart on the
conveyor belt.
v) Repeat i) to iv) above at the lowest and
highest speeds.
13) If for any reason the setting of the tm3 timer is
not correct return to step 1) and repeat all the
steps.