2)
If you only need to select the timer group for the
current product number and not adjust any of the
timer group properties then
a) Select the soft key adjacent to NO, and go
back to the Engineer Mode section.
!
CAUTION
Although NO was selected the group will be changed
to the group letter selected in 1).
else
b) Select the soft key adjacent to YES, and
proceed to step 3).
3)
Press the soft key adjacent to tm3[G].
4)
a)
If the display opposite appears, press the soft
key adjacent to NO.
else
b)
Proceed to step 5).
5)
Set the product line to its mid range speed.
6)
Press the soft key adjacent to SIGNAL SHIFT.
a)
For packaged or separate products
1 Place the metal contaminant at the rear /trailing edge
of the product.
2 Pass the product with the metal contaminant
attached through the detector aperture, ensuring that
the product does not slip or skew.
3 Use the cursor Up and Down keys to adjust the
Signal Shift so that the reject device operates as the
front edge of the pack reaches it.
4618 - 021
OPERATING INSTRUCTIONS
In the following displays 'X' represents the timer group A, B or C as
selected at step 1); tmxx represents the timer type that is currently
selected for this timer group.