Command Identifier - 'Q' Qa Lists And Displays; Qa Operator Commands; Qa Inspector Commands - Safeline Signature Operating And Instruction Manual

Table of Contents

Advertisement

Command Identifier - 'Q'
All QA relevant displays (see 'QA Operator Mode' and 'QA Inspector Mode' flowcharts in the manual) will be
represented as a separate subseries from the main protocol letters. The elements of the subseries would be
identified by a number corresponding to the numbered position in the flowcharts mentioned. Thus the subseries
would be identified primarily by its letter 'Q' and then by its position within the 'Q' subseries by a number.
In the following table both the leading letter and the subseries element number are shown:

QA Operator commands

1,2
Command
Direction
'Q01,' m ',' n
in/out
',' o
'Q01?'
in
'Q02' ....
-----------
'Q09'

QA Inspector commands

1,2
Command
Direction
'Q10,' n
in/out
'Q11,' n
in/out
'Q11?'
in
'Q12,' n
in/out
'Q12?'
in
'Q13,' m ',' n
in/out
',' o
'Q13?' m ',' n
in
'Q14,' n
in/out
'Q14?'
in
132
3
Test Sample Material
m = product number
n = Sample
n = 0 : Ferrous
n = 1 : None - Ferrous
n = 2 : Stainless Steel
o = Test Result
o = 0 : Failed
o = 1 : Passed
Request last values of m, n, and o used by the detector.
Reserved for later use
3
Printing
n = 0 : Print(ing) all settings
n = 1 : Print(ing) shift reports
Line identification number
n = 4 digits number
Line Identification Number ?
Printer Selected
n = 0 : NO
n = 1 : YES
Printer selected ?
Sample Size Registration
m = Product number, a two digit number in the range [0..20].
n = 0 : Ferrous Sample
n = 1 : None - Ferrous Sample
n = 2 : Stainless Steel Sample
o = Sample size in mm, a two digit number in the form X.X
(E.g. 09 = 0.9 mm
Sample Size Registration ?
Shift Report options
n = 0 : Reject Relay Operations OUT
OUT
n = 1 : Reject Relay Operations OUT
n = 2 : Reject Relay Operations IN
OUT
n = 3 : Reject Relay Operations IN
Shift Report options ?
QA Lists and Displays
Description
Description
Modified Settings
Modified Settings IN
Modified Settings
Modified Settings IN
APPENDIX D
4
Type
P
X
4
Type
X
X
X
P
X
4618-021