Safeline Signature Operating And Instruction Manual page 119

Table of Contents

Advertisement

16) Select the soft key adjacent to the SYNC.
SHIFT.
When the Sync. Shift is selected the detect led will be
lit and the buzzer will sound permanently.
a) Pass the product with the metal contaminant
through the detector aperture, ensuring that
the product does not slip or skew.
b) Use the cursor Up and Down keys to adjust
the Sync Delay so that the packs are rejected
accurately and consistently.
17) Press the Enter key to accept the new settings.
18) Press the soft key adjacent to ETC.
19) Press the soft key adjacent to REJECT TIME.
a) Place the metal contaminant at the front or
rear edge of the product package.
b) Pass the product with the metal contaminant
attached through the detector aperture,
ensuring that the product does not slip or
skew.
c) Use the cursor Up and Down keys to adjust
the Reject Time until the pack is rejected
accurately and repeatedly.
20) Press the Enter key to accept the new settings.
21) Press the Enter key a second time to proceed to
the next display.
22) The display shown opposite will appear for five
seconds before returning to the Engineer Mode
display
4618 - 021
OPERATING INSTRUCTIONS
103

Advertisement

Table of Contents
loading

This manual is also suitable for:

Signature 2

Table of Contents