Safeline Signature Operating And Instruction Manual page 140

Table of Contents

Advertisement

1 2
Command
Direction
'P' n
in/out
'P?'
in
'Q'
---------
'q' m ',' n
in/out
'q?' m
in
'R' n
out
'R?'
in
'r' n
in/out
'r?'
in
'S' a ',' b ',' c ',' d
in/out
'S?'
in
's' n
in/out
's?'
in
124
3
Product Number.
n = The value of the detectors product number. A two digit
number, with leading zeroes, in the range [0...20].
Current product number ?
SEE LATER FOR DETAILS OF IDENTIFIER 'Q'
Automatic tracking enable
m = product number, a two digit number in the range [1..20]
n = 0 : NO
n = 1 : YES
Automatic tracking enabled (for product number m) ?
Detection status
n = 0 : Normal
n = 1 : Detection
Detection Status ?
Pack sensor fitted
n = 0 : NO
n = 1 : YES
Pack sensor fitted ?
Security codes
Each of these is a four digit number in the range [0..9999].
a = Supervisor code
b = Engineer code
c = Viewing code
d = QA Inspector code
Security codes ?
Pack sensor calibration
n = 0: Pack sensor calibration finished.
n = 1: Pack sensor calibration start
Note
The host sends 's1' to start calibrating. The detector will respond
's1' during calibration and 's0' when calibration is finished.
Pack sensor calibration
Description
APPENDIX D
4
Type
P
X
P
X
X
X
X
4618-021

Advertisement

Table of Contents
loading

This manual is also suitable for:

Signature 2

Table of Contents