16) Press the 'Enter' key to store the new settings in
memory.
17) Test the sensitivity of the detector by passing
metal samples through the aperture of the
detector (preferably positioned on or placed in
the product) and note the results.
18) If there are other product types to be inspected
repeat this procedure from step 2).
19) Press 'PROG/EXIT' to return to the running
mode.
Notes
1)
As a guide...If during manual setup the sensitivity
is adjusted below 100, then improved spherical
30
OPERATING INSTRUCTIONS
performance may be achieved by switching
'Operating Frequency' to LOW and repeating the
manual setup procedure, omitting step 4).
Under these conditions, to ensure that the best
sensitivity is achieved, it is recommended that
the manual setup procedure is carried out for
both settings of 'Operating Frequency' (i.e. HIGH
and LOW). A comparison should then be made
between the two sets of results and the most
favourable settings selected.
If during manual setup sensitivity is adjusted
below 100 and 'Operating Frequency is already
switched to LOW, then switch 'Power drive' to
LOW and repeat the manual setup procedure,
omitting step 4) and step 5).