BRP Rotax 915 i A Series Maintenance Manual page 62

Aircraft engine
Table of Contents

Advertisement

Points of Inspection
* no periodic maintenance (require-
ment after the first 25 hours of
operation)
Visual inspection of the fuses.
Check the wastegate lever for free run-
ning and correct position
Lubricate the wastegate lever.
Check gear set (pittings)
Check wear on tooth of overload
clutches
Check overload clutches
Check wear on the intermediate shaft
Change torsion shaft
Flushing the cooling system if massive
deposits on the expansion tank or radi-
ator cap and/or if the coolant manufac-
turer required an change interval.
05–20–00
Page 12
June 01 2019
BRP-Rotax
MAINTENANCE MANUAL LINE
Interval Operating hours
25*
50
100
X
X
11) Checking the wastegate lever
X
X
X
X
12) Checking the propeller gear box
13) Flushing the cooling system
when replacing the coolant
Chapter
Reference
200
600
1000
12–20–00
Turbocharger
12–20–00
Turbocharger
X
See Heavy
Maintenance
72–10–00
X
See Heavy
Maintenance
72–10–00
X
See Heavy
Maintenance
72–10–00
X
See Heavy
Maintenance
72–10–00
X
See Heavy
Maintenance
72–10–00
12–20–00
Flushing the
Signa-
ture
Chap.
Chap.
Chap.
Chap.
Chap.
cooling
system
Effectivity: 915 i A Series
Rev. 1

Advertisement

Table of Contents
loading

Table of Contents