Non Compliance With The Coolant Specification - BRP Rotax 915 i A Series Maintenance Manual

Aircraft engine
Table of Contents

Advertisement

Step
Exceeded for longer than 30 min.
Step

NON COMPLIANCE WITH THE COOLANT SPECIFICATION

General note
Step
05–50–00
Page 20
June 01 2019
BRP-Rotax
MAINTENANCE MANUAL LINE
Table 1: Temperature exceeded less than 30 min.
Procedure
2
Inspect all further systems for correct functioning.
3
Carry out detailed inspection of the affected engine components such as:
• Leakage check on the cooling system.
• Check that the cylinder head attachment is fitted securely. If any of the
cylinder head nuts are loose, proceed as instructed in sec. "Excess tem-
perature of over 180 °C (356 °F) and/or for longer than 30 min.".
• Check all coolant fittings (feed/outflow) for secure fit.
Table 2: Exceeded for longer than 30 min.
Procedure
1
The whole cooling system must be inspected, repaired or overhauled in ac-
cordance with the BRP-Rotax instructions for continued airworthiness.
2
Inspect all further systems for correct functioning.
3
Carry out detailed inspection of the affected engine components.
4
Check compression by carrying out a differential compression check.
5
All cylinder heads and cylinders must be removed and subjected to a de-
tailed check including hardness testing. See chapter 72-00-00 of the Heavy
Maintenance Manual.
Use only coolant as recommended in the current Operators Manual
Non compliance with the coolant specification
Procedure
1
When a incorrect coolant is used, then the coolant system has to be
flushed.
See
Chapter 12-20-00 section Flushing the cooling system.
2
Fill expansion tank with new coolant (highest point of the coolant system).
See
Chapter 12-10-00 section Coolant
ATTENTION
check/replenish.
Effectivity: 915 i A Series
Rev. 1

Advertisement

Table of Contents
loading

Table of Contents