BRP Rotax 915 i A Series Maintenance Manual page 61

Aircraft engine
Table of Contents

Advertisement

Points of Inspection
* no periodic maintenance (require-
ment after the first 25 hours of
operation)
Drain oil from oil tank.
Check the oil tank and clean the oil
tank if contaminated.
Refill oil tank with approx. 3 litres of oil.
For oil quality, see Operators Manual
latest edition.
Inspect and clean screen in turbo oil
sump.
Install new oil filter
(4
In the case more than 30% of operation with leaded fuel e.g.: AVGAS 100 LL
Inspect the fuel system on the engine
side for leaks.
Inspect the fuel system for damages.
Check the ECU and its mountings.
Read out the ECU fault memory (fault
and data logs).
Check the FUSE BOX and its
mounting.
Effectivity: 915 i A Series
Rev. 1
BRP-Rotax
MAINTENANCE MANUAL LINE
Interval Operating hours
25*
50
100
7) Oil change
X
X
(4
X
X
(4
X
X
(4
X
X
(4
X
X
X
(4
X
8) Fuel system
X
X
9) Engine management
X
X
10) FUSE BOX
Reference
200
600
1000
12–20–00
Oil change,
Flushing the
X
12–20–00
Oil change,
Cleaning the
12–20–00
Flushing the
Purging the
oil system
12–20–00
Turbo sump
12–20–00
12–20–00
Fuel system
X
12–20–00
12–20–00
Read out the
ECU data
X
Chapter
Signa-
ture
oil circuit
oil tank
oil circuit,
screen
Oil filter
change
Checking
ECU
memory
05–20–00
Page 11
June 01 2019

Advertisement

Table of Contents
loading

Table of Contents