(9) Verify aircraft is positioned so that it can be freely turned 45° (± 5°) clockwise (to the
right).
(a) Make sure area around aircraft is clear.
(b) Make sure that WX-PA tester can be moved with the aircraft.
(c) Make sure adequate cable is deployed from the external power cart to allow the
aircraft to turn 45° to the right.
(10) Power up the WX-PA Portable Analyzer unit.
• After the WX-PA completes self-test, the MODE MENU will be displayed.
(11) On the WX-PA, select "Continuous Out" on the MODE MENU, then press the MENU/
ENTR button once (so that WX-PA indicates "PAUSED" and not "RUNNING").
(12) On the WX-PA, press the FLAPS/A button to select top mount antenna configuration.
(13) On the WX-PA, select a cardinal bearing of 0° and a range of 55 NM.
• Use F1 and F2 buttons to adjust range and the F3 and F4 buttons to adjust
bearing.
(14) On the WX-PA, with "Continuous Out" still selected on the MODE MENU, push the
MENU/ENTR button once so that the WX-PA indication changes from "PAUSED" to
"RUNNING".
EFFECTIVITY: 0001 - 0008, 0010 - 0050, 0052, 0054 -
0267 PRE SB 500-31-024
EA500 Aircraft Maintenance Manual — 06-117751
© 2020 Eclipse Aerospace, Inc.
Temporary Revision No. 34-21
34-40-50
CONFIG A
Page 505
Sep 30/20