P22201-3 adapter, make sure that the pitot probe drain hole is covered with tape.
If needed, lubricate with Pitot adaptor lubricating fluid (Part Number LF5050).
NOTE: No other lubricating fluid is permitted. Malfunction of the equipment in
flight is possible.
(d) Connect the Static Test Hose Assembly ; (Nav Aids PN E500-5160)
Barfield Pitot/Static Tester DPS500 Ps connection
(e) Connect the other end of the Static Test Hose Assembly
the Static Port Adaptor (Nav Aids, SS53515-4-4)
(f) Connect the Static Port Adaptor (Nav Aids, SS53515-4-4)
port with the connected fitting to the top port and finger tighten the screws to seat
the seals over the Static ports.
(3) Use tape to seal the opposite-side static port.
NOTE: Make sure to select a tape that does not leave any adhesive residue on the
Static port when the test is complete.
(4) Power on the Barfield Pitot/Static Tester DPS500 by selecting OPERATE and PUMP
switches to ON. Wait for the Barfield Pitot/Static Tester DPS500 to confirm the
settings.
• After a successful self-test sequence, the system changes to the Warm Up
mode.
(5) Press ROC Ps RATE to select the ROC control aim, enter 4000 and press the Enter
button.
(6) Press ALT Ps to select the ALT control aim, enter 30000 and press the Enter button.
• The system starts to control to the new set point.
(7) Press SPEED Qc and enter 200 then press Enter. Wait for at least a 15 second
stabilization period after the altitude and airspeed achieve these new air data
parameter set point values to continue.
(8) Press LEAK MEASURE/CONTROL to change to LEAK MEASURE MODE.
(9) Press RATE TIMER.
(10) Press F3.
• After the Waiting and Timing intervals are complete, the Barfield Pitot/Static
Tester DPS500 displays Timed Rates.
(11) Check that the maximum ROC is 100 ft/min or less and the maximum Rt CAS is 2
kts/min or less.
• If the leak rate is not within tolerances, refer to Leak Testing in the Barfield Pitot/
Static Tester DPS500 and Connecting Hoses
AMM-34-10-00-071-701-003
DPS500 leak check altitude value recorded in Leak Testing the Barfield Pitot/
Static Tester DPS500 and Connecting Hoses subtask from the value obtained in
this section in order to get a corrected total system leak value.
(12) Press LEAK MEASURE/CONTROL to return to CONTROL MODE.
EFFECTIVITY: NOTED
EA500 Aircraft Maintenance Manual — 06-117751
and subtract the Barfield Pitot/Static Tester
© 2020 Eclipse Aerospace, Inc.
Temporary Revision No. 34-21
(12)
(1)
.
(12)
to the top fitting of
(10)
.
(10)
to the left Static
SUBTASK
34-10-00
Sep 30/20
to the
Page 509