(d) Connect the Static Test Hose Assembly ; (Nav Aids PN E500-5160) (long hose)
(12)
to the Barfield Pitot/Static Tester DPS500 Ps connection. Connect other end
of long hose
(9)
to the top fitting of the Static Port Adaptor (Nav Aids, SS53515-4-4)
(e) Connect the Static Port Adaptor (Nav Aids, SS53515-4-4)
port with the connected fitting to the top port and finger tighten the screws to seat
the seals over the static ports.
NOTE: The right static upper port can be tested from the left static lower port by
connecting the short hose to the lower port connection on the Static Port
Adaptor. The aircraft's left lower port is connected to the right upper port
and the left upper port is connected to the right lower port by aircraft
design. Refer to
(5) Connect the Barfield Pitot/Static Tester DPS500 to the aircraft using the Air Data
Accessories Kit (NavAids P/N ADA500MD-945) as follows:
NOTE: When installing the pressure test adapters, make sure that the seal is good
by applying a firm force to seat the adapter on the probe.
NOTE: The P22201MD-4 adapter contains a built-in seal that covers the Pitot/AOA
probe drain hole. If using the P22201-3 adapter, the drain hole must be
covered with teflon or vinyl tape.
NOTE: The Pitot/AOA probes with a drain hole near the base of mast, must have the
drain hole covered. Failure to do so will result in a failure of this test.
(a) Connect the Pitot Test Hose Assembly
Pitot/Static Tester DPS500. DO NOT OVERTIGHTEN.
(b) Connect the opposite end of the hose to the NAV Aids P22201MD-4 adapter.
(c) Install the NAV Aids P22201MD-4 adapter to the Pitot/AOA Probe. Make sure
that the internal seal of the adapter covers the pitot probe drain hole. If using the
P22201-3 adapter, make sure that the pitot probe drain hole is covered with tape.
If needed, lubricate with Pitot adaptor lubricating fluid (Part Number LF5050)..
NOTE: No other lubricating fluid is permitted. Malfunction of the equipment in
flight is possible.
(d) Connect the Static Test Hose Assembly ; (Nav Aids PN E500-5160)
Barfield Pitot/Static Tester DPS500 Ps connection
(e) Connect the other end of the Static Test Hose Assembly
the Static Port Adaptor (Nav Aids, SS53515-4-4)
(f) Connect the Static Port Adaptor (Nav Aids, SS53515-4-4)
port with the connected fitting to the top port and finger tighten the screws to seat
the seals over the Static ports.
(6) Use tape to seal the opposite-side static port.
NOTE: Make sure to select a tape that does not leave any adhesive residue on the
static port when the test is complete.
(7) Select WOffW on the WOW test box.
(8) Set the transponder to STBY on the PFD.
EFFECTIVITY: NOTED
EA500 Aircraft Maintenance Manual — 06-117751
(12)
to the quick-connect cross
Fig. 503, Sheet 1
© 2020 Eclipse Aerospace, Inc.
Temporary Revision No. 34-21
(11)
. Connect the static short hose
(10)
to the left static
(3)
to the Pt connection
(2)
(1)
.
(12)
to the top fitting of
(10)
.
(10)
to the left Static
(10)
.
on the Barfield
(12)
to the
34-10-00
Page 523
Sep 30/20