Kenwood TK-2170 Series Function Reference page 84

Hide thumbs Also See for TK-2170 Series:
Table of Contents

Advertisement

18 DTMF
Configuration using KPG-101D
Configuring the Transpond (Refer to FPRG 6.10.2
Decode Tab - Transpond (Trunking).)
Configuring the Alert Tone (Refer to FPRG 6.10.2
Decode Tab - Alert Tone (Trunking).)
18.3.9 Stun
Stun can be used to disable the transceiver by means of
a transmitted DTMF code, for example, if the transceiver
is stolen.
The transceiver multiplexes the Stun Code on Tone and
starts transponding when the transceiver receives the
Stun Code. Then, the transceiver executes the operation
configured for Stun Code Response.
The operation configured for Stun Code Response is
stored even if the transceiver is turned OFF. The status
of Stun Response is reset only when the transceiver
receives the Stun Reset code.
Stun Code and Stun Code Response can be configured
by using KPG-101D.
Table 18-7 Stun Configuration
Operation
Stun Code
Stun Code is a standby code for Stun.
Stun Response is the operation of the
transceiver when the Stun Code
matches. The following operations are
available for Stun Response.
Stun Code Response
• Transmit Inhibit: Disables transmit
capability.
• Transceiver Inhibit: Disables transmit
and receive capability. All transceiver
functions are disabled.
Note: The transceiver does not enter Emergency Mode if Stun is
enabled.
Configuration using KPG-101D
Configuring the Stun Code (Refer to FPRG 6.10.2
Decode Tab - Stun Code (Stun).)
Configuring the Stun Response (Refer to FPRG
6.10.2 Decode Tab - Stun Code Response.)
72
Index
Contents
Condition
Confidential
18.3.10 Auto Reset Timer
The Auto Reset Timer controls the duration from when
the DTMF code matches to when the code is
automatically reset.
The Auto Reset Timer can be configured by using KPG-
101D. Transceiver operation after the Auto Reset Timer
expires can also be configured.
Table 18-8 Auto Reset Timer Operation
Configuration
Off
The Auto Reset Timer does not activate.
LED, Alert Tone, Monitor, and the display
1 to 300 s
return to their previous statuses when
configured time elapses.
Table 18-9 Transceiver Operation after the Auto Reset
Timer Expires
Item
The DTMF code shown on the DTMF
LCD
Number Display disappears when the Auto
Reset Timer expires.
The Selective Call Alert LED stops blinking
LED
when the Auto Reset Timer expires.
The transceiver stops intermittently emitting
Alert Tone
the Alert Tone when the Auto Reset Timer
expires.
The matching status of the DTMF is reset
Monitor
when the Auto Reset Timer expires.
Configuration using KPG-101D
Configuring the Auto Reset Timer (Refer to FPRG
6.10.2 Decode Tab - Auto Reset Timer (Auto
Reset).)
18.3.11 Clear to Transpond
Clear to Transpond forces the transceiver to wait while
other users are using a channel before starting to
transpond.
Clear to Transpond can configured to be enabled or
disabled by using KPG-101D.
Note: Clear to Transpond is available only in Conventional Group.
Configuration using KPG-101D
Configuring the Clear to Transpond (Refer to
FPRG 6.10.2 Decode Tab - Clear to Transpond.)
Operation
Operation
FUNC (K)/Ver. 1.01