20.7.1 Fleet/ ID (Own)
FleetSync ID is the 7-digit ID consisting of a 3-digit Fleet
number (100 to 349) and a 4-digit ID number (1000 to
4999).
This ID is used for the PTT ID, for making a call and for
FleetSync data communications.
FleetSync ID can be configured by using KPG-101D.
Configuration using KPG-101D
Configuring the Fleet (Refer to FPRG 6.12.1
General 1 Tab - Fleet (Own).)
Configuring the ID (Refer to FPRG 6.12.1 General
1 Tab - ID (Own).)
20.7.2 Unit ID Encode Block
The Unit ID Encode Block is the FleetSync ID range used
to make a call.
It is possible to limit the FleetSync ID range by using
KPG-101D. The FleetSync ID configured in the ID List
can be used even if the ID is outside the Unit ID Encode
Block range.
If Unit ID Encode Block is not configured; the transceiver
can call all FleetSync IDs.
The following FleetSync IDs can be called with Unit ID
Encode Block.
Table 20-14 Available FleetSync ID
Interfleet Call Configuration
Unit ID Encode
Block
On (Check)
Unit ID Encode Block
On
in all Fleets
Off
All Fleet IDs
Configuration using KPG-101D
Configuring the Unit ID Encode Block (Refer to
FPRG 6.12.1 General 1 Tab - Unit ID Encode
Block.)
FUNC (K)/Ver. 1.01
Off (Uncheck)
Unit ID Encode Block
in Fleet
All IDs in Fleet (Own)
Confidential
20.7.3 FleetSync Baud Rate
FleetSync Baud Rate is the data baud rate for the MSK
modem.
The FleetSync Baud Rate configuration of both the
transmitting and receiving parties must be the same.
FleetSync Baud Rate can be configured by using KPG-
101D. Below is a list of available baud rates.
Table 20-15 Available FleetSync Baud Rates
FleetSync Baud Rate
Enables data communication at
1200 bps.
1200 bps
This configuration is recommended
for normal communications.
The transceiver can send more data
in a shorter time as compared with
1200 bps.
However, errors are more likely to
2400 bps
occur due to the faster rate.
In addition, the available data
communication area is smaller than
for 1200 bps.
Configuration using KPG-101D
Configuring the FleetSync Baud Rate (Refer to
FPRG 6.12.1 General 1 Tab - FleetSync Baud
Rate.)
20.7.4 Message Display Type
Message Display Type can be used to configure the
display when receiving a Status Message or Short
Message.
Message Display Type can be configured by using KPG-
101D. The following methods are available for Message
Display Type.
Table 20-16 Message Display Type Operation
Message Display
Type
"Status Message/ Short Message"
appears on the display when the
transceiver receives a call. The
Fixed
message is scrolled on the display if
the message is longer than 9
characters.
"Status Message/ Short Message"
appears for 3 seconds and Selcall ID
Alternate
appears for 2 seconds alternately
when the transceiver receives a call.
Note: The previous CH/GID appears on the display when any key
is pressed while a message is displayed.
20 FLEETSYNC