Kenwood TK-2170 Series Function Reference page 121

Hide thumbs Also See for TK-2170 Series:
Table of Contents

Advertisement

21.3 List Scan (TK-3173 only)
List Scan can be used to scan all Zone-CH/GIDs added in
the Scan List Table.
The following CH/GIDs can be scanned:
A CH/GID in a Zone that Scan Add is selected in Scan
List Table by using KPG-101D
A CH/GID added to the Scan List with the Scan
Delete/Add key
The transceiver always scans Priority Channel even if the
Priority Channel is not configured in the target zone when
a Priority Channel is configured.
"List" must be selected from the Scan Type to enable List
Scan.
Transceiver Operation
Starting the Scan
1. Press the Scan key.
The transceiver starts scanning.
"SCAN n" and the "
display. The zone number configured for the
Scan List can be entered in "n".
Exiting from Scan Mode
1. Press the Scan key while the transceiver is
scanning.
The "
" icon disappears and the transceiver
finishes scanning.
Configuration using KPG-101D
Configuring the Scan Type (Refer to FPRG 6.9.8
Scan Type.)
Assigning functions to the PF keys (Refer to
FPRG 6.8 Key Assignment.)
FUNC (K)/Ver. 1.01
" icon appear on the
Confidential
21.4 Priority Scan
Priority Scan can be used to scan the high priority
channels regardless of the configuration in each channel.
The transceiver monitors the Priority Channel with
Lookback even if the transceiver is receiving a normal
channel using Single Scan, Multi Scan or List Scan when
a Priority Channel is configured.
The transceiver scans the Priority Channel in the
following conditions:
When Priority Channel is in a different Zone from the
scanning Zones while executing the Single Scan.
When Priority Channel is in a different Zone from the
scanning Zones while executing the Multi Scan.
When Priority Channel is in a different Zone from the
scanning Zones configured with the Scan List Table
while executing the List Scan.
The transceiver scans Priority Channels with the cycle
configured in the Lookback Time A or Lookback Time B
edit box in the Scan Information window when the
transceiver executes Single Scan, Multi Scan or List Scan.
Priority Channel can be configured in the following ways
by using KPG-101D.
Table 21-5 Priority Scan Operation
Priority Scan
The channel configured by KPG-101D is
Fixed
configured as Priority Channel.
The transceiver scans the selected channel as
Priority Channel.
Selected
Priority Channel cannot be configured by using
KPG-101D.
The transceiver scans channels configured by a
user as Priority Channel. Priority Channel can
Operator
be changed in Priority-channel Configuration
Selectable
Mode when the Scan key is pressed and held
for 2 seconds.
Note:
Lookback can be used to monitor the presence of a
signal on the Priority Channel while receiving a call on a
normal channel during the Priority Scan.
The Group ID in Trunking System cannot be configured
for Priority Channel.
The transceiver does not look back to the Priority
Channel while the transceiver pauses scanning in
Trunking System.
21 SCAN
Operation
109
Contents
Index

Hide quick links:

Advertisement

Table of Contents
loading