Kenwood TK-2170 Series Function Reference page 119

Hide thumbs Also See for TK-2170 Series:
Table of Contents

Advertisement

Table 21-3 Transceiver Operation during Scan
(Conventional Group)
Configuration
The transceiver pauses scanning when
the received QT/DQT matches. Dropout
Delay Time activates when the QT/DQT
matching status is reset. The
transceiver resumes scanning after the
Dropout Delay Time elapses.
QT/DQT Operation
The transceiver transmits on Revert
Channel when the PTT switch is
pressed. The transceiver starts
counting down the Dwell Time when the
transmission ends, then resumes
scanning when the Dwell Time elapses.
The transceiver pauses scanning when
the received QT/DQT matches. The
transceiver does not emit the received
audio and waits to receive an Optional
Signaling.
The transceiver resumes scanning after
the Dropout Delay Time elapses when
QT/DQT - Optional
the QT/DQT does not match the
Signaling AND
configured QT/DQT while waiting to
Operation
receive an Optional Signaling.
The transceiver emits the received audio
and Alert Tone or starts transponding
when the received Optional Signaling
matches the Optional Signaling
configured for the transceiver. The
transceiver stands by on the channel
when the Optional Signaling matches.
The transceiver pauses scanning when
the received QT/DQT matches. The
transceiver emits the received audio and
waits to receive an Optional Signaling.
The transceiver mutes the received
audio and resumes scanning after the
Dropout Delay Time elapses when the
QT/DQT - Optional
QT/DQT does not match the configured
Signaling OR
QT/DQT while waiting to receive an
Operation
Optional Signaling.
The transceiver pauses scanning if the
received Optional Signaling matches.
The transceiver pauses scanning on the
current channel regardless of the QT/
DQT until the Optional Signaling is
reset.
Trunking System
The transceiver functions as configured in the Zone
Edit window (Trunking System) > Audio Control
dropdown list.
FUNC (K)/Ver. 1.01
Operation
Confidential
Table 21-4 Transceiver Operation during Scan
(Trunking System)
Configuration
The transceiver stops scanning if the
decoded LTR ID matches the target
Group ID.
The Dropout Delay Time starts counting
down if the decoded LTR ID matching
status is reset. The transceiver resumes
LTR ID Operation
scanning after the Dropout Delay Time
elapses.
The transceiver transmits on Revert GID
when the PTT switch is pressed. The
Dwell Time starts counting down when
the transmission ends, then resumes
scanning when the Dwell Time elapses.
The transceiver pauses scanning if the
decoded LTR ID matches the target
Group ID. The transceiver does not emit
the received audio and waits to receive
an Optional Signaling.
The transceiver resumes scanning after
the Dropout Delay Time elapses when
LTR ID - Optional
the decoded LTR ID does not match the
Signaling AND
configured Group ID while waiting to
Operation
receive an Optional Signaling.
The transceiver emits the received audio
and Alert Tone or starts transponding
when the received Optional Signaling
matches the Optional Signaling
configured for the transceiver. The
transceiver stands by on the Group ID if
the Optional Signaling matches.
The transceiver pauses scanning if the
decoded LTR ID matches the target
Group ID. The transceiver emits the
received audio and waits to receive an
Optional Signaling.
The transceiver mutes the received
LTR ID - Optional
audio and resumes scanning after the
Signaling OR
Dropout Delay Time elapses when the
Operation
decoded LTR ID does not match the
configured Group ID while waiting to
receive an Optional Signaling.
The transceiver emits the Alert Tone or
starts transponding when the received
Optional Signaling matches the Optional
Signaling configured for the transceiver.
Note: The transceiver jumps to the LTR ID having the higher
priority when the transceiver receives an LTR ID having
higher priority than the current LTR ID in Trunking System.
21 SCAN
Operation
107
Contents
Index

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents