22 EMERGENCY MODE
Configuration using KPG-101D
Configuring the Emergency Recognition (Refer to
FPRG 6.14.15 Emergency Recognition.)
22.1.16 Emergency LED
Configure whether the Transmit LED lights when the
transceiver transmits in Emergency Mode and the Busy
LED lights when the transceiver receives in Emergency
Mode.
LED can be configured to light by using KPG-101D.
Configuration using KPG-101D
Configuring the Emergency LED (Refer to FPRG
6.14.16 Emergency LED.)
22.1.17 Background Transmission
This function allows the transceiver to multiplex a
1630 Hz tone on the transmitted audio and emit a tone
every second while in Emergency Mode.
The transceiver does not mute since the tone is
transmitted with lower deviation than normal. The
receiving party can easily recognize that the caller is in
Emergency Mode since the tone is multiplexed with audio
signal.
The transceiver can be configured to emit the tone by
using KPG-101D.
Configuration using KPG-101D
Configuring the Background Transmission (Refer
to FPRG 6.14.17 Background Transmission.)
22.1.18 Man-down Switch Type
Man-down Switch Type is an input port used for the Man-
down tilt switch.
Man-down Switch Type can be configured by using KPG-
101D.
Configuration using KPG-101D
Configuring the Man-down Switch Type (Refer to
FPRG 6.14.18 Man-down Switch Type (Man-
down).)
118
Index
Contents
22.1.19 Man-down Delay Time
Man-down Delay Time is the duration between when the
Man-down tilt switch is turned On and when the
transceiver enters Emergency Mode.
Emergency function activates when the Man-down tilt
switch is enabled. The Man-down Delay Time prevents
Emergency Mode from being entered unintentionally.
The Man-down Delay Time can be configured by using
KPG-101D.
Configuration using KPG-101D
Configuring the Man-down Delay Time (Refer to
FPRG 6.14.19 Man-down Delay Time (Man-
down).)
22.1.20 Man-down Pre-alert
Man-down Pre-alert is one of the Alert Tones that sounds
when the Man-down tilt switch is going to be activated in
a short time.
When the Man-down tilt switch is enabled unintentionally,
the transceiver emits the Pre-alert to notify a user that the
tilt switch is enabled before activating the Emergency
function.
The Man-down Pre-alert can be configured by using
KPG-101D. The Man-down Pre-alert must be configured
for a shorter duration than the Man-down Delay Time.
Configuration using KPG-101D
Configuring the Man-down Pre-alert (Refer to
FPRG 6.14.20 Man-down Pre-alert (Man-down).)
22.1.21 Man-down Logic Type
The logic of the Man-down tilt switch (Optional switch)
can be configured.
Man-down Logic Type can be configured in the following
way by using KPG-101D.
Table 22-5 Man-down Logic Type Operation
Man-down Logic Type
Active Low
Active High
Confidential
Operation
When the Man-down switch is
enabled, the input port becomes
Low.
When the Man-down switch is
enabled, the input port becomes
High.