• Drive and steer functions can only be performed after
the DOS override switch (on the platform console) has
been engaged. Drive and steer functions can be oper-
ated at normal speed;
• All the structure movements (Mast and Jib Lift, Swing)
remain unaffected by the DOS.
Main Mast Limit Switch
The main mast limit switch determines whether the plat-
form is in Transport position (mast fully lowered) or in Ele-
vated position. When the main mast limit switch is tripped:
• Max. driving speed is reduced from approx. 5.5 km/h
to approx. 0.75 km/h.
Secondary Mast Limit Switch
The secondary mast limit switch is used to detect when
the mast is close to the max. elevation. When the second-
ary mast limit switch is tripped:
• Max. driving speed is reduced from approx. 0.75 km/h
to approx 0.4 km/h.
Battery Charger Interlock
When the battery charger is connected to the mains, the
information is sent to the control system. If the battery
charger is connected to the mains:
• All the movements are cut out from the platform con-
sole if the MACHINE SETUP , CHARGER INTERLOC is
set to CUTOUT ALL;
• Drive and steer functions are cut out if the MACHINE
SETUP , CHARGER INTERLOC is set to DRIVE ONLY.
Battery Discharge Indication
The battery status is continuously monitored by the MAS-
TER MODULE. Indication is given to the operator through
both the MDI and the platform console panel. Functions
limitations are applied depending on three status:
charged, discharged (which corresponds to 70% dis-
charge) and deeply discharged (which corresponds to
80% discharged).
If the battery is charged, no function limitation is applied.
If the battery is discharged:
• The max. driving speed, in transport position, is
reduced by 50%. Out of transport position, driving
speed is not affected;
• Mast Lift Up, Jib Lift Up and Swing maximum speeds
are reduced (same parameter as for tilted condition is
used);
• Mast Lift Down and Jib Lift Down can be operated at
normal speed.
If the battery is deeply discharged:
• Mast Lift Up and Jib Lift Up are cut out;
• The max. driving speed is limited at 0.4 km/h, whatever
the platform position is;
• Max. swing speed is reduced;
• Mast Lift Down and Jib Lift Down can be operated at
normal speed.
31210090
SECTION 3 - THEORY OF OPERATION

Personality Settings and Calibration

Functions performances may be altered by changing the
applicable personality settings or calibrating different ele-
ments of the control system.
Refer to section 9 for the applicable procedures.