SECTION 10 - DIAGNOSTIC TROUBLE CODES

10.3 DTC CHECK TABLES

0-0 Help Comments

DTC
FAULT MESSAGE
EVERYTHING OK
001
GROUND MODE OK
002
FUNCTIONS LOCKED OUT -
008
SYSTEM POWERED DOWN
RUNNING AT CUTBACK - OUT
0010
OF TRANSPORT POSITION
MODEL CHANGED - HYDRAU-
259
LICS SUSPENDED - CYCLE
EMS
FUNCTION SELECTED BUT
0023
TRIGGER SWITCH OPEN
FUNCTION SELECTED BUT
0027
LIFT ENABLE SWITCH OPEN
DRIVE PREVENTED - TILTED &
0028
ELEVATED
RUNNING AT CREEP - MAX
0029
ELEVATION
10-2
DESCRIPTION
The normal help message in Platform
Mode. Displays on the analyzer only.
The normal help message in Ground
Mode. Displays on the analyzer only.
After 2 hours without activity, the Control
System enters a low-power state to pre-
serve battery charge. Displays on the ana-
lyzer only; the MDI's LED is blinking with
the display Off.
Drive speed is limited while the mast is
elevated.
Displays on the analyzer only.
The model selection has been changed.
One of the drive joystick functions was
activated, but the trigger switch was not.
The Mast or the Jib joystick was activated,
but the enable switch was not.
Drive is prevented while the platform is not
in transport position and the chassis is not
level.
Drive speed is limited while the mast is
fully extended.
Displays on the analyzer only.
– JLG Lift –
CHECK
• Normal operation should resume after a power
cycle.
• Check battery charge, condition, etc.
• Fully stow the platform.
• Check that the mast switches are securely
mounted.
• Check the mast switches wiring :
@ +Vbatt : CR4(A), CR23(1), CR23(4), CR23(3),
CR23(6), CR5(3), CR5(5), CR2(31), CR2(20).
@ -Vbatt : CR4(B), CR4(C), CR23(2), CR23(5).
• Check ANALYZER->MACHINE SETUP->MODEL.
• Refer to §9 for proper personality settings and cali-
brations.
• Release joystick and allow to center.
• Check if the joystick is obstructed or jammed.
• Proceed with a joystick calibration.
• Check Joystick voltages (refer to Section 8).
• Check if the trigger switch is damaged.
• Check trigger switch output : J2(5).
• Release joystick and allow to center.
• Check if the joystick is obstructed or jammed.
• Proceed with a joystick calibration.
• Check Joystick voltages (refer to Section 8).
• Check if the enable switch is damaged.
• Check the enable switch output : J1(18).
• Check that the machine is tilted. If so, lower the plat-
form and reposition the machine to a level surface.
• Fully stow the platform.
• Check that the tilt sensor is securely mounted and
its wire connected.
• Check the tilt sensor wiring :
@+Vbatt : CR9(B), CR9(C), CR2(7), CR3(7).
@ -Vbatt : CR9(A).
• Check the tilt sensor setting; if necessary, proceed
with a sensor calibration.
• Fully stow the platform.
• Check that the mast switches are securely mounted.
• Check the mast switches wiring :
@ +Vbatt : CR4(A), CR23(1), CR23(4), CR23(3),
CR23(6), CR5(3), CR5(5), CR2(31), CR2(20).
@ -Vbatt : CR4(B), CR4(C), CR23(2), CR23(5).
31210090