Machine Setup Programming Information - JLG TOUCAN 10E Service And Maintenance Manual

Hide thumbs Also See for TOUCAN 10E:
Table of Contents

Advertisement

9.3 MACHINE SETUP PROGRAMMING
INFORMATION
In case of complete system reset (Controller change, Per-
sonality settings reset), the following logic shall be fol-
lowed:
Shaded entries are not available for the selected market.
Configuration Digit
1
(Model #)
2
(Market)
3
(Drive Cutout)
4
(Ground Alarm)
5
(Load)
6
(Soft Touch)
7
(Gate)
8
(Charger Interlock)
31210090
Setting Range
0
Toucan 10E
0
CE
0
0=NO - Drive NOT PREVENTED while elevated.
1
1=YES - Drive Prevented while elevated.
0
0=NOT INSTALLED
1
1=DESCENT - Vehicle alarm will function during lift down motions.
2
2=MOTION - Vehicle alarm will function during drive and all motions.
0
0=NOT INSTALLED - Load sensing system (LSS) is not fitted to the
vehicle
1
1=CUTOUT PLT - Load sensing system (LSS) is fitted, and Platform
Controls are prevented in the event of an overload. Ground Controls
remain functional.
2
2=CUTOUT ALL - Load sensing system (LSS) is fitted. Platform and
Ground Controls are prevented in the event of an overload.
0
0=NOT INSTALLED - Soft touch frame is not fitted to the vehicle.
1
1=INSTALLED - Soft touch frame is fitted to the vehicle. In the event of
soft touch device actuation during a motion, only the reverse move-
ment wil be allowed.
0
0=NOT INSTALLED - Articulated gate is not fitted to the platform.
1
1=INSTALLED - Platform is fitted with an articulated gate. Platform
and Ground Controls are prevented when gate is open.
0
0=DRIVE ONLY - Drive motion prevented when vehicle is charging.
1
1=CUTOUT ALL - All motions are prevented while vehicle is charging.
Table 9-1. Machine Setup Programming Information
SECTION 9 - JLG CONTROL SYSTEM
Description
– JLG Lift –
Default Setting
0
0
0
0
1
0
0
1
9-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents