JLG TOUCAN 10E Service And Maintenance Manual page 122

Hide thumbs Also See for TOUCAN 10E:
Table of Contents

Advertisement

SECTION 10 - DIAGNOSTIC TROUBLE CODES
DTC
FAULT MESSAGE
STEER VALVE - SHORT TO
33355
GROUND
STEER VALVE - OPEN CIR-
33356
CUIT
FLOW DIRECTION VALVE -
33358
SHORT TO GROUND
FLOW DIRECTION VALVE -
33359
OPEN CIRCUIT
SWING VALVE - OPEN CIR-
33362
CUIT
MAST VALVE - OPEN CIRCUIT
33365
PROPORTIONAL RELIEF
33366
VALVE - SHORT TO BATTERY
PROPORTIONAL RELIEF
33367
VALVE - SHORT TO GROUND
10-10
DESCRIPTION
The Steer valve driver is shorted or the
valve coil is faulty (open) or discon-
nected.
The Steer valve coil is faulty or discon-
nected or the coil driver is faulty.
The Flow Direction valve driver is shorted
or the valve coil is faulty (open) or discon-
nected.
The Flow Direction valve coil is faulty or
disconnected or the coil driver is faulty.
The Swing valve coil is faulty or discon-
nected or the coil driver is faulty.
The Mast valve coil is faulty or discon-
nected or the coil driver is faulty.
The Proportional Relief valve driver output
is detected short to +Vbatt.
The Proportional Relief valve driver output
is shorted.
– JLG Lift –
CHECK
• Check the valve driver output CR3(11) for a short
circuit with -Vbatt.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• If the wiring is correct, the driver circuit is damaged
: replace the Slave controller.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• Replace the Slave controller if the coil and its har-
ness are correct.
• Check the valve driver output CR3(34) for a short
circuit with -Vbatt.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• If the wiring is correct, the driver circuit is damaged
: replace the Slave controller.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• Replace the Slave controller if the coil and its har-
ness are correct.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• Replace the Slave controller if the coil and its har-
ness are correct.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• Replace the Slave controller if the coil and its har-
ness are correct.
• Check the following Slave controller driver output
CR3(23) for a short circuit with +Vbatt.
• Check the valve coil for correct impedance (refer to
Section 8).
• If the harness and the coil are correct and if the fault
appears at start up : Replace the Slave controller.
• Check the valve driver output CR3(23) for a short
circuit with -Vbatt.
• If the wiring is correct, the driver circuit is damaged
: replace the Slave controller.
31210090

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents