SECTION 7 - HYDRAULICS
6. Connect battery plug and check for proper opera-
tion of the machine.
7.4 SWING MOTOR
NOTE: Refer to Section 5 of this manual for swing motor
removal procedure.
Figure 7-11. Swing Motor
Ports Identification
Port A: Swing Left
Port B: Swing Right
Port DR: Drain Port - Plugged
7-6
7.5 CYLINDERS HOLDING VALVES
Mast Cylinder Holding Valve
Figure 7-12. Mast Cylinder Holding Valve - Removal/
Valve Removal
ENSURE THAT THE MAST IS FULLY LOWERED (OR SAFELY SUP-
PORTED) BEFORE DISMOUNTING THE VALVE. DISCONNECT
BATTERY PLUG TILL THE REPAIRS ARE COMPLETED.
1. Remove chassis hoods. Swing the structure 90° to
the right. Fully raise the mast and install suitable
blockings to support mast section #2 (Refer to Sec-
tion 5). Lower the mast until mast section #2 rests
on blockings. Turn power off at ground controls. Dis-
connect battery plug.
2. Tag, disconnect and cap mast cylinder hydraulic
lines and ports (1).
3. Remove the spring ring (7) from the elbow adapter.
4. Unscrew coil nut (2), remove the manual override
device (3), the O-ring (4) and the coil (5).
5. Unscrew the valve mounting screw (6) and plug the
cylinder port (3/8" BSPP).
– JLG Lift –
Installation
31210090