5.3.1.6

Pin assignment of the Industrial Ethernet interface (X1 P1)

Table 5- 18
Interface view
Note
Use of Siemens cables
We recommend that you only use original Siemens cables and connectors (refer to the
section Ordering data (Page 120)) to connect to the Ethernet socket of the reader. If plug-in
connectors from other manufacturers are used, it may be difficult or even impossible to
remove the plug from the reader.
5.3.1.7

Grounding connection

On the top of the reader there is a blind drill hole (M4 x 8) for grounding. Tighten the screw
with a torque of ≃ 1.5 Nm.
Hazardous voltage due to lightning strikes
Death or serious injury may occur as a result of lightning strikes to antennas mounted
outside buildings.
If the reader is operated with antennas mounted outside buildings, it is imperative that the
reader is electrically connected to the ground potential.
NOTICE
Installation only in protected areas
The antenna can be installed in the protected part of a building. When implementing your
lightning protection concept, make sure you adhere to the VDE 0182 or IEC 62305
standards.
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
Pin assignment of the Industrial Ethernet interface (reader end)
WARNING
Pin
Pin assignment
1
Transmit Data (+)
2
Transmit Data (-)
3
Receive Data (+)
4
Terminated
5
Terminated
6
Receive Data (-)
7
Terminated
8
Terminated
Readers
5.3 SIMATIC RF650R
129