Siemens SIMATIC RF600 Series System Manual page 223

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

Power
Interfaces
Plug connection
Mechanical specifications
Material
Color
Tightening torque (at room temperature)
Permitted ambient conditions
Ambient temperature
Conditions relating to UL approval
Degree of protection
Shock resistant to EN 60068-2-27
Vibration to EN 60068-2-6
Design, dimensions and weight
Dimensions (H x W x D)
Weight
Standards, specifications, approvals
Proof of suitability
MTBF
The values differ for different dimensions/materials of the mounting surface.
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
ETSI
FCC
During operation
During transportation and storage
6.2 SIMATIC RF615A
6GT2812-0EA0x
≤ 2 W
≤ 1 W
30 cm coaxial cable with RP-TNC coupling
(for connection of the antenna cable)
PA6 V0, silicone-free
Black
≤ 1.5 Nm (when mounted on a flat surface)
-20 ... +70 °C
-40 ... +85 °C
for indoor use only (dry location)
mounted on height below 2 m
Coaxial connectors and cables shall com-
ply with NFPA70 art. 820 part V
IP67
(IP rating is not investigated by UL)
50 g
2)
20 g
2)
52 x 52 x 16 mm
60 g
FCC: cULus
1190 years
Antennas
223