Siemens SIMATIC RF600 Series System Manual page 248

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

Antennas
6.4 SIMATIC RF640A
Make the following settings to ensure that the maximum permitted radiated power of the
antenna is not exceeded:
● Antenna gain: 4 dBi (or 7 dBiC)
● Radiated power: ≤ 1360 mW ERP (or 31.35 dBm ERP)
Converted into EIRP: ≤ 2240 mW EIRP (or 33.5 dBm EIRP)
● Use of cable loss associated with the antenna cable.
Limitations in the USA and Canada
Note
Limitation of the radiated power (FCC)
RF600 systems that are put into operation in the USA and Canada must not exceed the
following radiated power with an RF640A antenna:
• 4000 mW EIRP (or 36 dBm EIRP)
Make the following settings to ensure that the maximum permitted radiated power of the
antenna is not exceeded:
● Conducted power P (dBm) of the RF600 reader: < 30 dBm
● Antenna gain G
● Cable loss a
P (dBm) ≤ 30 dBm - (G
Limitations in China
Note
Limitation of the radiated power (CMIIT)
RF600 systems that are put into operation in China must not exceed the following radiated
power with an RF640A antenna:
• 1460 mW ERP (or 31.35 dBm ERP)
Converted into EIRP: 2400 mW EIRP (or 33.8 dBm EIRP)
Make the following settings to ensure that the maximum permitted radiated power of the
antenna is not exceeded:
● Antenna gain: 4.3 dBi (or 7.3 dBiC)
● Radiated power: ≤ 2000 mW ERP (or 33 dBm ERP)
Converted into EIRP: ≤ 3250 mW EIRP (or 35 dBm EIRP)
● Use of cable loss associated with the antenna cable.
248
(dBi) in the FCC frequency band: ≤ 4.3 dBi
i
(dB): ≥ 1 dB
k
- 6 dBi) + a
i
k
System Manual, 11/2018, J31069-D0171-U001-A21-7618
SIMATIC RF600

Advertisement

Table of Contents
loading

Table of Contents