Presetting of the EPC memory of industrial Siemens transponders RF6xxT
The first 12 bytes of the EPC memory ("0x00 - 0x0B") are preset. As of byte 13 ("0x0C") the
EPC memory is not preset.
Table 7- 1
Address UID
0x00
...
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
In the following table, these values are described in greater detail.
1)
Note that the RF6xxT transponders cannot be disabled using a kill password.
Table 7- 2
Explanation of the values
Transponder
Year produced
type
RF620T = 0x3E
2015 = 0x0F
2016 = 0x10
RF622T = 0x5E
...
RF625T = 0x8E
...
RF630T = 0x3F
...
RF640T = 0x40
...
RF645T = 0x84
...
RF680T = 0x44
...
RF682T = 0x64
The consecutive number is counted absolutely as of the respective production date and is therefore unique.