Siemens SIMATIC RF600 Series System Manual page 296

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

Antennas
6.6 SIMATIC RF650A
Electrical data
Range
Impedance
Polarization
VSWR (standing wave ratio)
Power
Interfaces
Plug connection
Mechanical specifications
Material
Color
Tightening torque (at room temperature)
Permitted ambient conditions
Ambient temperature
Degree of protection
Shock resistant to EN 60068-2-27
Vibrations according to EN 60068-2-6
Design, dimensions and weight
Dimensions (H x W x D)
Weight
Standards, specifications, approvals
Proof of suitability
MTBF
The values differ for different dimensions/materials of the mounting surface.
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
296
During operation
During transportation and storage
See section "Maximum read/write ranges of
transponders (Page 341)"
50 Ω
Circular
≤ 1.45
≤ 2 W
RP-TNC coupling (for connection of the an-
tenna cable)
Pocan
Pastel turquoise
≤ 2 Nm
-25 ... +75 °C
-40 ... +85 °C
IP65
30 g
2)
10 g
2)
198 x 198 x 60 mm
680 g
CE (according to RED), FCC (Title 47, Part
15.247), cULus
946 years
System Manual, 11/2018, J31069-D0171-U001-A21-7618
6GT2812-0GB08
SIMATIC RF600

Advertisement

Table of Contents
loading

Table of Contents