Siemens SIMATIC RF600 Series System Manual page 137

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

Channel spacing
Modulation methods
Multitag capability
Typical transmission time per byte
Supply voltage
Maximum permitted current consumption
Maximum permitted current consumption via
the digital I/O interface
Current consumption (on standby), typical
Current consumption (at 1000 mW transmit power), typical
Current consumption (at 2000 mW transmit power), typical
Interfaces
Antenna connectors
Power supply
Digital I/O interface
Digital inputs
Digital outputs
Ethernet interface
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
ETSI
FCC
CMIIT
ARIB (STD-T107)
Write access
Read access
20 V input voltage on the reader
24 V input voltage on the reader
30 V input voltage on the reader
20 V input voltage on the reader
24 V input voltage on the reader
30 V input voltage on the reader
20 V input voltage on the reader
24 V input voltage on the reader
30 V input voltage on the reader
600 kHz
500 kHz
250 kHz
200 kHz
ASK: DSB modulation & PR-ASK modulation
encoding, Manchester or Pulse Interval (PIE)
Yes
2 ms
0.15 ms
24 V DC (20 ... 30 V DC)
2 A
1 A
220 mA / 4.4 W
190 mA / 4.5 W
150 mA / 4.5 W
450 mA / 9.0 W
370 mA / 8.9 W
300 mA / 9.0 W
610 mA / 12.2 W
500 mA / 12.0 W
410 mA / 12.3 W
4x RP-TNC
1x RS422, M12 (8-pin)
1x M12 (12-pin)
4
4
1x RJ45 (8-pin), 100 Mbps
Readers
5.3 SIMATIC RF650R
6GT2811-6AB20-xAA0
2)