7.3.3

The "Settings - Reader Interface" menu item

With the "Settings - Reader interface" menu item, the interface parameters of up to two
readers can be read. If the communication module is connected to an S7 controller, the
configurations are made via the controller. In this case, the set values are only displayed in
the WBM and cannot be edited.
The settings of each interface are identically structured and divided into the following areas:
● Basic settings
● Reader parameters
Figure 7-6
The "Settings - Reader Interface" menu item
Basic settings
In this section, you define the basic settings for the selected reader interface.
Table 7- 4
Description of the basic parameters
Parameter
Ident system category
Ident devices/system
SIMATIC RF166C
Operating Instructions, 12/2019, C79000-G8976-C578-01
Parameter value
Standard device
RF300 fast protocol
RF600 Reader
Freeport
Empty module
General reader
RF200 general
RF290R
RF300 general
RF380R
RF300 Gen 2 general
RF380R Gen 2
MV400/MV500
Default value
Description
Standard device
Selection of the Ident system category. The
various Ident system categories differ in the
communication protocols they use.
Depending on the selection made, different
parameter values are displayed in the following
"Ident devices/system" parameter.
General reader
Selection of the device/system connected to the
communication module.
Depending on the selection made, different
parameters are shown or hidden in the follow-
ing "Reader parameters" section.
If no device is connected to the interface, select
the "Empty module" parameter value.