Siemens SIMATIC RF600 Series System Manual page 35

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

Intralogistics (separator)
Power supply using Power over Ethernet
Distributed small gate
Trigger by light barrier on DI
Figure 4-2
Scenario: Intralogistics (separator)
In this example scenario, items must be distributed to the correct storage location in a
transport container via a separator. The transponders attached to the transport containers
are always evenly aligned. The transponders in this scenario are transponders of the type
SIMATIC RF630L. The conveyor belt has a maximum width of approximately 80 cm in this
example. The maximum transport speed of the conveyor belt is 2 m/s.
In this scenario, a SIMATIC RF615A with a SIMATIC RF615A external antenna is used as
the reader. With the RF615R, a reader combining multiple advantages is used. In addition to
its compact design, this low-cost reader is also characterized by low cabling requirements.
When a transport container passes the light barrier
the transponder on the transport containers and forwards it to the SIMATIC S7 controller.
The SIMATIC S7 controls the separator
transponder information.
The SIMATIC RF650M mobile reader is used in this example for additional evaluation and
visualization of the article data directly on site.
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
4.2 Possible system configurations
Separator setting by means of DQ
Individual read point
Mobile data acquisition
, the reader reads the information from
of the conveyor system depending on the
RF600 system planning
35