Electrical data
Range
Impedance
Polarization
VSWR (standing wave ratio)
Power
Interfaces
Plug connection
Mechanical specifications
Material
Color
Tightening torque (at room temperature)
Permitted ambient conditions
Ambient temperature
Degree of protection
Shock resistant to EN 60068-2-27
Vibrations according to EN 60068-2-6
Design, dimensions and weight
Dimensions (H x W x D)
Weight
Status display
Standards, specifications, approvals
Proof of suitability
MTBF
The values differ for different dimensions/materials of the mounting surface.
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
During operation
During transportation and storage
6.8 SIMATIC RF680A
6GT2812-2GB08
See section "Maximum read/write ranges of
transponders (Page 341)"
50 Ω
Linear, circular (can be switched over)
≤ 1.45
≤ 2 W
RP-TNC coupling (for connection of the an-
tenna cable)
Pocan
Pastel turquoise
≤ 2 Nm
-25 ... +75 °C
-40 ... +85 °C
IP65
30 g
2)
10 g
2)
198 x 198 x 60 mm
690 g
1 LED
CE (according to RED), FCC (Title 47, Part
15.247), cULus
218 years
Antennas
329