4.12 Volume Control

The Volume Control function applies to the loudspeaker output only. Volume levels at the keypad are
programmed individually – refer to page: 14 on how to access the menu.
4.12.1 Volume Controls
The following volume on each sound can be controlled: Entry, Exit, Alarm, Fire, Tamper, Day
alarm, Chime, and Intelligent Set.
Volume controls: 0 = Completely silent. 1 = Silent but sounds a beep when the system is set
2-7 volume of tones (7 = loudest).
4.12.2 Code Stops Sound
If this function is enabled, then once an alarm has been generated (even if the code is not
programmed for that area) the alarm will be silenced, and a 'Misoperation (Abort) signal' will be
sent. The area will remain set until a code or tag is presented that is assigned to that area.
4.12.3 Entry/Exit Keypads Only
If this function is disabled, any entry and exit tones will be heard through the main sounder. If
enabled, the entry and exit tones will only be heard through the keypad speaker.
4.12.4 Alert Kps Only
If this function is enabled, any 'Alert' tones will be heard on the Keypad only and not the main
sounder. If disabled, the alert tones will heard through both.
4.12.5 Silent Technical Alert
If this function is enabled then any technical alerts will be silenced, e.g line fault, ARC call fail.
4.12.6 Use Main Sounder
If enabled, all volumes that are programmed as 2-7 will activate on the main sounder. If
disabled, the sounder will only activate on activations programed on volume 6-7.
Volume Control Programming
1. Press or to scroll to 'VOLUME CONTROL'. Press .
2. 'A Entry' will be displayed. Enter the volume and press . Repeat
for all areas.
3. 'Code Stops Sound' will be displayed. Press [ or ] to enable or
disable and press .
4. 'E/E Keypads Only' will be displayed. Press [ or ] to enable or
disable and press .
5. 'Alert Kps Only' will be displayed. Press [ or ] to enable or
disable and press .
6. 'Silent Tech Alert' will be displayed. Press [ or ] to enable or
disable and press .
7. 'Use Main Sounder' will be displayed. Press [ or ] to enable or
disable and press . The Engineer menu will be displayed.

4.13 Alarm Response

The Alarm Response function controls how certain activations are to perform.
4.13.1 Silent 1st Alarm
If this function is selected as 'confirmed', then the first alarm to activate on the system will be
silent, but only if another input activates (i.e. a confirmed alarm) then the alarm will activate and
the alarm tones will be heard. This option is only valid once the system has been set for 3
minutes and not if the entry time has started.
4.13.2 Disable Confirm On Entry
To comply with BS8243 clauses 6.4.3 and 6.4.4, this option should be set to YES to disable
confirmation once the entry procedure has started. For use with BS8243 option 6.4.5, this
option should be 'No'. If 'Disable Confirm On Entry' is set to YES this option will disable ALL
confirmation signals on entry. If NO the confirmation signals are enabled on expiry of entry time.
Page: 19
VOLUME CONTROL?
A Entry
Code Stops Sound
No
E/E Keypads Only
No
Alert Kps Only
Yes
[0]
[0]
[0]
[1]