Appendix E. Content Types - Pyronix Enforcer 32-WE Programming And Installation Manual

Wireless alarm system
Hide thumbs Also See for Enforcer 32-WE:
Table of Contents

Advertisement

A p p e n d i x E .
No.
Description
1
Final Set, System Rearm, ATM set, Secure set system
2
System set by auto set, Auto set cancelled by user, Forced Set, System unset by auto unset
ATM disarmed
3
Access Exit Request, Special Unset
4
Set Fail, Set Fail (with zone)
5
Burglary Alarm, Entry/Exit alarm, Day alarm, Perimeter, Perimeter Alarm, Gas Alarm, No Zone
Activity - sent, Tamper Alarm, Tamper On Zone, Flood Alarm, Keybox Alarm
6
Burglary Alarm Once, Entry/Exit alarm once, Day alarm once, Interior Alarm Once, Perimeter
Alarm Once, Fire Alarm Once, Gas Alarm Once, Holdup Alarm Once, Medical Alarm Once, PA
Alarm Once, Tamper Alarm Once, Flood Alarm Once, Keybox Alarm Once
7
Alarm Silenced
8
Confirmed Output, Confirmed Intruder, Confirmed Hold Up
9
Input Line OK, Telecom line OK, Input Line fail, STU Telecom Line OK
10
Low Volts, Detector fault, Detector Fault, Detector Masked, Device Restored, Device Fail,
Fuse 1, Fuse 2, Fuse 3, Fuse 4, Fuse 5, RS485 fault (not used), Telecom line fault, ID Line Short
Fault on a device at rearm, Radio supervision failure, Radio hub jamming, Radio low battery,
Battery Connect, Battery Disconnect, Battery Load Fail, Battery Critical, DIGI Fail Comms,
STU comms failure on STU input indication, Network Fault (IP panels), Excess Charge
Modem Failed, Warning Device Fault, Warning Device Fault Restore
11
Clock Set To, PC - Clock set to, Changed Code, Code Added, Deleted Code, Engineer Reset
Site Changed, Clock Set From, System Restart, Logs Cleared, Clean Started, CHC Call Failed
Logs nearly full, Engineer reset needed, Twin Device, Excess Current
12
Unset System
13
Engineer Access, Engineer Exit
14
Door Forced, Door Left Open
15
Tag at Reader
16
Invalid Tag
17
Zone Special Log Switcher Opened
18
Zone Special Log Switcher Closed
19
Zone Special Log Opened
20
Zone Special Log Closed
21
Ward Unset, Ward Silenced, Ward Zone Unset, Ward Zone Silenced, Shunt Closed
22
Ward Set, Ward Zone Set, Shunt Opened
23
Ward Alarm
24
Zone Walk Tested
25
Burglary Restore, Entry/Exit Restore, Day alarm restore, Interior Alarm Restore, Perimeter
Restore, Detector Masked Restore, Detector Fault Restore, Fire key Restore, Gas Restore
Fuse fail restore, 2 key PA restore, Tamper Restore, Tamper On Zone Restore, iD line short
restore, Case tamper restore, Radio Supervision restore, Flood Alarm Restore, Radio Jamming
restore, Radio hub jam restore, Radio low battery restore, System (SAB) tamper restore
Keybox Restore
26
Test Call
27
Restore of mains fail alarm, Mains Fail Alarm
28
Fire Alarm, Fire key pressed, Fire Restore, Duress Code, Holdup Alarm, Hold Up Restore
Code Guessing, Radio fob PA, PA Alarm, Two key PA, Radio Fob PA restore, PA Restore
29
Medical Alarm, Medical Alarm Restore
30
Zone Omitted at Rearm, Day Alarm Zone Omitted, Zone Omitted, Day Alarm Zone Omitted
Restore, Zone Omitted Restore, Fire Zone Omitted, Fire Zone Omitted Restore, Zone Force Armed
31
Stopped Set, Abort
Enforcer Programming Manual
C o n t e n t T y p e s
Page: 54