Engineer Tests Programming: Test Siren, Battery Load Test and
Test Outputs
1. Press or to scroll to 'ENGINEER TESTS'. Press .
2. 'Sound to play' will be displayed. Press .
3. 'Walk Test' will be displayed. Press .
4. 'Soak Test' will be displayed. Press .
5. 'Test Siren' will be displayed. Press . Any outputs programmed
as 'Siren Any' and 'Strobe Any' will trigger. Press  to exit.
6. 'Do Battery Load Test' will be displayed. Press  to perform a
battery load test, the voltage will be displayed, followed by 'Battery
Passed' if the test has been successful. Press .
7. 'Test Outputs' will be displayed. Press  to perform a test on any
output type. For example if '0006' is entered, and the  key is
pressed, a 'Confirmed Any' test will be activated. Press  to
cancel the test.
8. Press  to go back to the Engineer menu.
Engineer Tests Programming: Test Communications and Start
CHC SMS update.
1. Press or to scroll to 'ENGINEER TESTS'. Press .
2. 'Sound to play' will be displayed. Press .
3. 'Walk Test' will be displayed. Press .
4. 'Soak Test' will be displayed. Press .
5. 'Test Siren' will be displayed. Press .
6. 'Do Battery Load Test' will be displayed. Press .
7. 'Test Outputs' will be displayed. Press .
8. 'Test Communications' will be displayed. Press  to send a test
signal to the ARC.
9. 'Testing to CHC' will be displayed. Press  to send a test signal to
the Castle Host Computer.
10. Press  to go back to the Engineer menu.

4.20 Diagnostics

The Enforcer 32-WE diagnostic function shows all system readings, including power supplies, input
status, wireless signal and wireless battery status.
The diagnostic resolution is: Voltage: 0.1V, Current: 0.01A.
4.20.1 View PSUs
This function shows all power readings for; the endstation, any ZEMs, any output expanders, any
keypads and readers.
4.20.2 View Inputs
This function shows all the input statuses on the Enforcer 32-WE (including Wireless and any
expanders connected). The resistances can be shown, or just the status; C = Closed, O = Open,
T = Tamper, - = Not learnt and F = Resistance fault. For wireless inputs; S = Supervision fault.
B = Battery fault.
NOTE: The endstation inputs are those of the I/O board if connected.
Enforcer Programming Manual
Page: 26
ENGINEER TESTS?
Test Siren?
Testing Siren...
Do Battery Load
Test?
Testing Battery
13.3V
Test Outputs?
OP Test
[0000]
ENGINEER TESTS?
Test
Communications?
Are You Sure?
Start CHC SMS
Update?
Testing to CHC
Pleae Wait...