Normally Open: Enables the system to respond correctly when detectors of 'normally open'
configuration are wired to the system. Alternatively converts input types which default to
'normally open' (e.g. Push to set) to operate with normally closed devices.
Confirm Group: If inputs are selected into the same confirm group, each input will only
generate an unconfirmed alarm (and will not generate a confirmed activation). This is useful
when two or more shock sensors are being activated by the same event. If a confirm group is
selected as '00', the inputs are not part of any group.
4.5.4 Input Description
A name and location can be entered here. The name will appear on the display if an alarm has
occurred; the location is used for a more detailed reference if required.
Change Inputs Programming
1. Press or to scroll to 'CHANGE INPUTS'. Press .
2. Press [ or ] to select the input to program (01-66). Press .
'Input Type' will be displayed. Press [ or ] to select the
input type or input the shortcut number (see Appendix B,
page 49 for all input type options.
3. Press 
4. 'Input Area' will be displayed. Select the Area's to be assigned to
the input and press .
5. 'Input Attributes' will be displayed. If any attributes are needed for
the input, press  and press [ or ] to select between the
attribute enable/disable options and press to go to the next
attribute.
6. 'Enter Name' will be displayed. Enter the name of the input and
press . This will be displayed if it is activated or when a fault
occurs.
7. 'Enter Location' will be displayed. Enter the location of the input
and press . This will be displayed if it is activated or when a
fault occurs after the name of the input has been shown.
8. Press [ or ] to select another input to program (01-66) or
press the key to return to the Engineer menu.

4.6 Assign Keypads/Readers

Any additional keypads or readers must be addressed correctly before enabling them in this function.
The Enforcer 32-WE keypad is automatically addressed as 0 on initial power up. Refer to page: 39 for
more information.
4.6.1 Address
Up to 3 x additional keypads or readers may be installed. Address 0 is used for the Enforcer 32-
WE on-board keypad.
NOTE: Each keypad has its own individual menu that programs the key-click volume, tag volume
and master volume. It will address a keypad, show the status of the keypad inputs (if
programmed), force the backlight on or off and the identification number of a tag (once a tag is
presented). The PA/Fire timer can be programmed. This menu also addresses the keypad.
To enter the keypad menu, press and hold the  key until 'SECURITY CODE' is displayed, and
then enter '2000'. This function is also used to address the keypad.
4.6.2 Type
[0] Keypad. [1] Reader. [2] Not Used.
4.6.3 Reader is
If a reader is installed, the following options can be assigned to the reader:
[0] Set Point: Reader used for setting and unsetting.
[1] Not Used: Reader disabled
[2] Access Control: If an access control system is installed then the reader must be
Enforcer Programming Manual
Page: 14
CHANGE INPUTS?
Input
[01]
Input 01
Input Type
[07]
Final Exit
Input Areas
[A
Input Attribtes?
Enter Name
_
Enter Location
_
]