Fault Indications
Fault
Description
485 Fail xxx
Device on RS-485
communications bus is
failing to communicate
correctly with the control
panel.
485/Comms
Displayed on keypad that
Lost
has not yet established
communications with End
Station
Keypad
Keypad address does not
display is
match any keypad enabled
BLANK
Keypad
More than one device
display
connected at the same
normal, but
address
KEYS
LOCKED OUT
Authorisation
The master manager will
need to give the Engineer
Required
access
Fault
Description
Battery Fuse failed,
OR Battery not present,
OR Battery volts low
Battery Fault
xxx
Battery Load Test has
failed
Bat Test Fail
XXX
Battery being powered
down
Bat Critical
XXX
Mains supply failed

Mains Fail

xxx
Power supply volts low
Low Volts
xxx
Enforcer Programming Manual
RS-485 BUS PROBLEMS
Solution
Identify device from the location/name and the device
type. Check device addressed correctly to match
programming. Ensure that 2 devices of the same type
do not share the same address. Check connections at
device, and cabling to it. If above correct, re-boot
device, followed by re-boot of End Station.
Part of routine initialisation procedure.
If persists, check display at other keypad(s) to confirm if
device failure at that keypad or complete system RS-
485 failure (temporarily attach additional keypad direct
to End Station if necessary).
Check keypad address, noting that a keypad at address
00 must be present to program system.
Also check "Assigning Keypads" menu in Engineer mode
set up correctly.
Correct addressing so that no overlaps. Then power
system down and up again to correctly reinitialise.
The option 'Allow Engineer Menu' will need to be
enabled by the master manager
POWER SUPPLY PROBLEMS
Solution
Note: This indication should be expected during
recharge after a mains failure.
The top line displays 'Control Panel' if it is a fault on the
endstation, if the Battery fault is on a ZEM/OPM 'xxx'
will show the device type and the top line the location
text if entered, if not it shows xxx-nn where nn is the
address of the ZEM/OPM.
Only displays if option selected.
Battery uncharged or capacity below specification may
need replacing. Same method as showing the device as
battery fault.
Protects battery from deep discharge damage during
extended mains failure. Same method as showing the
device as battery fault.
Note: System is now powered down
System detects mains frequency out of specification, as
well as voltage. Same method as showing the device as
battery fault. Note: 'AC FAIL' timer operative
Battery volts below normal 'battery fault' level during
mains failure. Same method as showing the device as
battery fault