into Engineer Mode. If the test is aborted, it will NOT be performed until the next day. This is
selected in SITE OPTIONS under "Do Battery Load Test". The test may also be performed as
required, under engineer control.
4.19.6 Test Outputs
The engineer can test all the Programmable Outputs on the Input/Outboard board and the output
module.
4.19.7 Test Communications
If the engineer is using SIA or Contact ID to signal events, this function can be used to send a
test signal to the Alarm Receiving Centre. It can also be used to test SMS signaling.
4.19.8 Start CHC SMS Update
If the engineer has set up SMS text messaging then this function needs to be used (after
enabling SMS calls in 'Set up Digi/SMS', the engineer mode must be exited to save all the data,
and then this function must be entered (this function is also in the master manager menu)).
The system will automatically carry out a test call to our Host Computer every two weeks. The
call is made via a premium rate number and the bill payer should be informed of the charge
(50p per call). Customers who have "BT Answer 1571" enabled may have difficulty in
connecting to the CHC.
Engineer Tests Programming: Walk Test
1. Press or to scroll to 'ENGINEER TESTS'. Press .
2. 'Sound to play' will be displayed. Use [ or ] to select the
different sounds. Press to exit.
3. 'Walk Test' will be displayed. Press .
4. Select the areas that are required to be walk tested and press .
5. A list of all inputs programmed for that area will be displayed on
the keypad. Once an input has been walk tested (i.e. the detector
has activated and deactivated) then the input will be taken off the
list.
6. Once all inputs have been tested, 'Walk Test Completed' will be
displayed. To exit the walk test function at any time press .
7. Press again to go back to the Engineer menu.
Engineer Tests Programming: Soak Control
1. Press or to scroll to 'ENGINEER TESTS'. Press .
2. 'Sound to play' will be displayed. Press .
3. 'Walk Test' will be displayed. Press .
4. 'Soak Control' will be displayed. Press .
5. Select the inputs that are required to be soak tested. Each input
should be entered, following by . Press once finished.
6. 'Soak Days Left' will be displayed. Select the number of days that
the inputs will be left on soak test and press .
7. 'Initial Soak' will be displayed. Enter the number of days the soak
test will revert to in the event a soak input is triggered during
testing. Press .
8. Press to go back to the Engineer menu.
Page: 25
ENGINEER TESTS?
Sound to play
No Sound
[00]
Walk Test?
Walk Test Areas
[ABCD]
Walk Test Inputs
Input 01
ENGINEER TESTS?
Sound to play
No Sound
Soak Control?
Soak Inputs [--]
Soak Days Left
Initial Soak
[00]
[00]
[00]