Change Timers; Date And Time; Exit Modes - Pyronix Enforcer 32-WE Programming And Installation Manual

Wireless alarm system
Hide thumbs Also See for Enforcer 32-WE:
Table of Contents

Advertisement

4.8 Change Timers

This function controls all timers of the Enforcer 32-WE.
4.8.1 Timers
For a list of all timers, refer to Appendix C, on page 50.
Most commonly used timers:
Entry Time (0-255 seconds), Exit Time (0-255 seconds), Siren Time (2-15 minutes), Confirm
Time (1-99 minutes), Wireless Supervision Time (0-99 hours).
NOTE: The timer for inputs on 'Soak Control' is in the function 'ENGINEER TESTS'.
Change Timers Programming
1. Press or to scroll to 'CHANGE TIMERS'. Press .
2. 'A Entry Time' will be displayed. Enter the time and press .
Refer to Appendix C, page 50 for all timers and enter the time on
the required function and press  for the next timer.
3. Press to return to the Engineer menu.

4.9 Date and Time

All log entries and the system display include the time and date. This is also programmed in the
Master Manager Mode.
NOTE: Please note that powering down the system will reset the time and date information.
4.9.1 Year, Month, Day, Hours, and Minutes
Enter the year, month, day, hours and minutes.
4.9.2 DST Adjust
Enable or disable the 'Day Saver Time Adjust' as required.
Set Date and Time Programming
1. Press or to scroll to 'SET DATE AND TIME'. Press .
2. 'Year' will be displayed. Enter the year and press . Repeat for
Month, Day, Hours and Minutes and press .
3. 'DST Adjust' will be displayed. Press [ or ] to enable or disable
the function and press .
4. Press to return to the Engineer menu.

4.10 Exit Modes

The 'Exit Modes' operate the Setting procedure of the Enforcer 32-WE system. The following Exit
Modes are available:
4.10.1 Exit Modes
[0] Timed: The Enforcer 32-WE system will set when the programmed 'Exit Time' has expired
(See 'Change Timers' on page 17).
NOTE: This is NOT suitable for systems installed to comply with BS8243.
[1] Final Door: The Enforcer 32-WE system will set when an input programmed as 'Final Exit' is
either closed (if the input was opened when setting started) or it is opened and closed. 'Final
door' is used for the 'lock set' operation; securing the lock completes the setting procedure and
unlocking starts the entry time.
[2] Timed/Final: The Enforcer 32-WE system will set when a 'Final Exit' input has been closed,
or when an 'Exit Time' has expired. The 'Final Exit' input will override any 'Exit Time'
programmed if opened/closed.
NOTE: This is NOT suitable for systems installed to comply with BS8243.
[3] Push to Set (PTS): The Enforcer 32-WE system will only Set when a 'Push to Set' button
has been pressed. This function will override the programmed Exit Time.
Page: 17
CHANGE TIMERS?
A Entry Time
[030]
SET DATE & TIME?
Year (00-99)
[07]
DST Adjust?
No
[0]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents