The Engineer Menu; Entering The Engineer Menu; Exiting The Engineer Menu; Useful Engineer Menu's - Pyronix Enforcer 32-WE Programming And Installation Manual

Wireless alarm system
Hide thumbs Also See for Enforcer 32-WE:
Table of Contents

Advertisement

2 . T h e E n g i n e e r M e n u
The Engineer Menu must be accessed in order to program all system configurations.
NOTE 1: All tamper alarms (including case tamper), will be disabled once in the Engineer menu.
NOTE 2: All personal attack and fire alarms will cause an alarm in the Engineer Menu.

2.1 Entering The Engineer Menu

Access to the Engineer menu will be allowed if the Enforcer 32-WE is unset. If set, the Enforcer 32-
WE must be unset first via a valid user code/tag/keyfob in order to gain access. If the 'Allow Engineer
Menu' function in the Master Manager Menu is set as 'No', the message 'Authorisation Required' will
be shown and access will be denied until this option is set as 'Yes'.
1. Enter the Engineer code (default 1111).
2. Press if any faults appear.
3. 'SET/UNSET SYSTEM' is displayed (see page:8).
4. Press .
5. 'FORCE ARM ON 1st INPUT' is displayed (see page:8).
6. Press .
7. 'SOFTWARE REVISION' is displayed.
8. Engineers Menu has been accessed.
Refer to page: 9 for all functions.
When the Engineer Menu is accessed, a high pitch tone is generated intermittently.
NOTE 1: It is recommended that a factory default (Clean Start) is performed after initial power up to
ensure that the correct defaults have been chosen (see page: 33).
NOTE 2: Refer to Appendix F, page: 55 for all fault code display descriptions.

2.2 Exiting The Engineer Menu

1. On a Main Menu Item (a menu that is in capital
letters), press  or scroll to 'EXIT ENGINEERS
MENU' and press .

2.3 Useful Engineer Menu's

WIRELESS DEVICE CONTROL (Page: 10): Learns and deletes all wireless inputs and bells. To
learn keyfobs enter the Master Manager menu and scroll to CHANGE CODES. (Refer to the user
manual)
CHANGE INPUTS (Page: 13): Programs all input types, attributes, areas and names and on the
Enforcer 32-WE.
ASSIGN KEYPADS/READERS (Page: 14): Assigns keypads and readers, and enables readers for
entry control. NOTE: Keypads and Readers must be addressed at the device and at the keypad.
CHANGE CODES (Page: 18): Changes the Engineer code and Master manager code. To change user
codes enter the Master Manager menu and scroll to CHANGE CODES. (Refer to the user manual).
CHANGE OUTPUTS (Page: 20): Programs any outputs and assigns output modules to the Enforcer
32-WE.
DIAGNOSTICS (Page: 26): Displays power, input status, wireless signal strength and wireless
battery levels.
PROGRAM ARC/SMS (Page: 30): Enables the modem (if connected) and allows signalling of
communication formats and SMS.
Enforcer
Time
Enter Your Code
SET / UNSET
SYSTEM?
FORCE ARM ON 1st
INPUT?
EXIT ENGINEER
MENU?
Page: 5
13:43 c
[
]
[01]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents