Installation Guide; Mains And Earth Wiring - Pyronix Enforcer 32-WE Programming And Installation Manual

Wireless alarm system
Hide thumbs Also See for Enforcer 32-WE:
Table of Contents

Advertisement

6 . I n s t a l l a t i o n G u i d e
NOTE 1: It is recommended that the Engineer menu is accessed prior to opening a powered Enforcer 32-
WE.
NOTE 2: If any new peripheral is installed (i.e. Modem, I/O board, Expander) it is recommended that the
Enforcer 32-WE is powered down (mains and battery).
1. Slightly unscrew the two screws
located at the bottom.
NOTE: Do not fully unscrew at
these can be used as a 'hanger' to
the rear casing as shown in Step
3.

6.1 Mains and Earth Wiring

It is important that the electrical earth connection is connected when connecting the 240V mains
supply to the Enforcer.
NOTE 1: Do not locate the mains cables next to internal cabling.
NOTE 2: Ensure that the Enforcer 32-WE is not mounted on any metal surfaces.
NOTE 3: That the mains cables should not be internally 'looped' as shown. This may interfere with
the wireless antenna's. Where possible it is recommended that all mains cables should be installed
through the area nearest the mains terminals as shown above.
NOTE 4: If cable management is an issue, a spacer is available: ENF/SPACER-WE
2. Unhinge the Enforcer 32-WE from
the top and pull down to disconnect.
NOTE: Take extra care when
removing the front of the Enforcer 32-
WE as modems, I/O boards etc may
be connected to the front.
Page: 35
3. Hang the front of the Enforcer
32-WE on the opening screws at
the bottom if required. Shown
below.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents